实际上是我们使用的命令不对,对于使用默认Z限位方案的Voron2.4来说,我们应该使用Z_ENDSTOP_CALIBRATE命令而不是PROBE_CALIBRATE命令,配置文件中也给了我们充分提示: 首先我们通过控制台将打印头归零,然后将打印头移动到热床中间位置: 当然后执行Z_ENDSTOP_CALIBRATE命令: 这时会弹出z补偿调整页面: 如果你的Fluidd控制...
positon_endstop是x限位的坐标。三叉戟的(0,0)坐标在正面看的左下角,X,Y限位在右上角,所以positon_endstop都是position_max。我把x的max稍微调小了一点,这是我试过了,250感觉有点偏。 speed啥的默认就行。homing_positive_dir,是归位方向。true,就是向max方向归位。positon_endstop在position_max,所以就是t...
// PROBE_CALIBRATE: Calibrate the probe's z_offset // QUERY_ADC : Report the last value of an analog pin // QUERY_ENDSTOPS: Report on the status of each endstop // QUERY_FILAMENT_SENSOR: Query the status of the Filament Sensor // QUERY_PROBE: Return the status of the z-probe //...
On klipperscreen, the Z value was 0.0. So I still don't get why I see The resulting switch offset is negative! Either the nozzle is still too far away or something else is wrong... when I run CALCULATE_SWITCH_OFFSET after CALIBRATE_Z. Or do I need to run CALCULATE_SWITCH_OFFSET ...
helper.speed) @@ -399,18 +431,28 @@ def calibrate_z(self): " new offset=%.6f" % (probe_zero, switch_zero, nozzle_zero, self.helper.switch_offset, offset)) self.gcmd.respond_info("Z-CALIBRATION: position_endstop=%.3f -"" offset=%.6f --> new z position_endstop=%.3f"...
ps.: There is a real need to familiarize oneself with the probe [support documents](https://github.com/KevinOConnor/klipper/blob/master/config/example-extras.cfg) before these instructions make sense! Here is some sample code to add to the config: [servo BFPTouch] set pin to the pin ...
修改klipper_z_calibration下的z_calibration.py内calibrate_z函数,如果最开始没有使用安装脚本而是直接复制的文件,则修改klippy/extras/z_calibration.py文件。之后记得要重启一次树莓派。 修改y_offset为0,一般在probing.cfg文件内。 修改switch_offset为一个比较大的值如1,在z_calibration.cfg文件内。
The Voron 2 went public beta at the beginning of January and there are already 21 printers built with many more currently in the build stage. So there is a demand for this and also plenty of testers. I would like to thank you for your efforts with Klipper and am eager to try out thi...
end_gcode: #A list of G-Code commands to run after each calibration command. #See docs/Command_Templates.md for the G-Code format. This can be used to #detach the probe afterwards. 32 changes: 32 additions & 0 deletions32firmware/klipper_configurations/klicky-bed-mesh-calibrate.cfg ...
Klipper · 3篇 很多小伙伴在装好Voron2.4以后不知道如何校准Z轴,喷嘴总是太高或太低,无法正常打印,使用PROBE_CALIBRATE命令调整Z补偿又无效,很是苦恼。下面一灰给大家讲解正确的方法! 实际上是我们使用的命令不对,对于使用默认Z限位方案的Voron2.4来说,我们应该使用Z_ENDSTOP_CALIBRATE命令而不是PROBE_CALIBRATE命令...