The maximum chemiluminescence intensity(ICLmax)and total area under the chemiluminescence intensity profiles were measured as a function ofp-iodophenol concentration, reagent solution pH, and reagent ionic strength.ICLmaxvalues were optimum at pH 8.5 and increased linearly with reagent ionic strength. ...
The effect of reagent pH and ionic strength was evaluated on the horseradish peroxidase (HRP)-luminol-p-iodophenol enhanced chemiluminescence assay. This assay was optimized for HRP andH2O2quantification during enzyme-mediated remediation of groundwater or wastewater contaminated with phenolic chemicals. ...
Chemiluminescence (CL) is an important method for quantification and analysis of various macromolecules. A wide range of CL agents such as luminol, hydrogen peroxide, fluorescein, dioxetanes and derivatives of oxalate, and acridinium dyes are used according to their biological specificity and utility....
Magnetic Bead and Nanoparticle Based Electrochemiluminescence Amplification Assay for Direct and Sensitive Measuring of Telomerase Activity. Anal. Chem. 2009, 81, 255-261. 17. Will, G.; Kudryashov, E.; Duggan, E.; Fitzmaurice, D.; Buckin, V.; Waghorne, E.; Mukherjee, S. Excited State ...
In this report, we describe a bromide-dependent chemiluminescence (Br-CL) assay that uses luminol as a chemiluminescence probe. The assay can distinguish between MPO and nonspecific peroxidase reactions. The MPO-specific reaction is believed to proceed in two steps: (i) the enzymatic generation of...
We developed a novel highly sensitive chemiluminescence (CL) method for BH(4). The principle of the proposed method is based on active oxygen formation induced by 1-methoxy-5-methyl phenazinium methyl sulphate (1-methoxy PMS) in the presence of dissolved oxygen. Furthermore, active oxygen is...
LIU E B; XUE B C.Ultrasensitive assay of rhein in medicine based on its enhanced luminol-K3Fe(CN)6 chemiluminescence reaction using the flow injection technique.Microchim Acta.2006.51-56Erbao Liu,Bingchun Xue.  Ultrasensitive Assay of Rhein in Medicine Based on its Enhanced Luminol-K 3 Fe...
Ultrasensitive Assay of Gatifloxacin at Picogram Level Based on Its Enhancing Effect on the Myoglobin-luminol Chemiluminescence Reaction. Xie X F,Shao X D,Yue Q L, et al. Analytical Letters . 2007Xie X , Shao X , Yue Q , et al . Ult rasensitive assay of gatifloxacin at picogram level ...
ChemiluminescenceFlow systemSulphiteWineA sensitive and rapid assay principle for sulphite was developed based on the suppression of luminol chemiluminescence by sulphite. EDTA greatly amplified this supression. Flow-through analysis was applied to evaluate the analytical potential for measuring sulphite ...
Chelating and pendant dual-antenna effect modulated ratiometric electrochemiluminescence system for lung cancer marker assay 漏2023 Elsevier B.V.Electrochemiluminescence of lanthanide coordination polymers (LCPs) has drawn researchers' torrential interest attributed to their con... L Cheng,Y Huang,Y Chen...