Cryo-TEM images with varying amounts of DOX in the liposome.Sun Min ParkJae Min ChaJungyong NamMin Sang KimSangJun ParkEun Sung ParkHwankyu LeeHyun Ryoung Kim
Images Courtesy of Simonas Masiulis, Radu Aricescu, MRC-LMB Cambridge and Evgenia Pechnikova, Abhay Kotecha, Thermo Fisher Scientific. 文件和下载 证书 搜索 显示0 条结果, 在上面搜索特定证书 申请COA Product Information Krios G4 Cryo-TEM Datasheet...
In many cases, the preparation of the TEM sample involves drying and staining steps, and the collection of images leads to the interaction of the specimen with the electron beam. Both aspects call for cautious interpretation of the resulting electron micrographs. Alternatively, a near-native ...
Differences in particle distribution resulting from different plasma treatments. Images created on a Tundra Cryo-TEM. Drulyte et. al. 2018, Acta Crystallographica Section D: Structural Biology Similarly, the Tundra Cryo-TEM has been used to help optimize the expression and purification systems for AA...
Cryo-TEM involves performing Transmission Electron Microscopy TEM analysis while keeping the sample at cryogenic temperatures, i.e. -170°C (or 103 K). Transmission Electron Microscopy (TEM)is a technique that images a sample using an electron beam. High energy electrons (80-200 keV) are transm...
Operating at 100 kV, the Tundra Cryo-TEM can generate high-contrast biological images down to 3.5 Å at medium throughput with its high-performance, fraction-enabled Thermo Scientific Ceta Camera. Meet your budget A wide range of funding proposals and grants were considered when designing the ...
Visualisation of 2D and 3D images were carried out using RELION11, Fiji47 or UCSF Chimera (1.11.2)48 depending on dimensionality. Model fitting and map validation An x-ray crystallographic-derived atomic model (PDBID: 2CIH) was fitted to the eight maps obtained with different data acquisition...
JEOL, a leading supplier of electron microscopes, has sold more than 2400 of its 100-120kV range TEMs worldwide. This versatile TEM is optimized for biological, polymer, and materials research. High contrast resolution is assured at 0.38nm poi...
Cryo-TEM images of MDA231 MPs separated by filtration: (a) Only a few MPs showed a bilayered morphology; (b) contamination is dominating the sample, probably medium proteins that did not wash out.Li...
Cryo-TEM service and support To ensure optimal system performance, we provide you access to a world-class network of field service experts, technical support, and workflow validation. See service solutions Electron Microscopy Funding Support Center ...