In the past this did not always work, with issues related to uppercase and lowercase letters. The user subroutine(s) could then not be found. If the .log file shows that the compiler is linked, and the .msg file mentions that the user subroutine is missing, then try this work...
It seems like in previous versions the Fortran compiler was linked to ABAQUS by calling the file ifortvars.bat from the ABAQUS CAE launcher as explained here: https://grabcad.com/tutorials/linking-abaqus-and-fortran The thing is that I do not find the ifortvars.bat file in ...
Abaqus is general-purpose FEM software developed by Simulia to address a wide range of problems. Abaqus does not offer any dedicated module for machining and, therefore, the user must manually model tools and workpiece geometries. The software offers a variety of user-subroutines to introduce and...
check the system requirements web page for the latest information on supported configurations.Requiremen...
I am assuming you are referring to the 2014 release. Use of Autodesk Simulation Composite Analysis 2014 plugins with Abaqus 6.13-1 is not supported. Please see attached release notes for supported platforms. While there is a workaround, as Dean Rose said above, the plugins with 6.13-1 have...
POSITION=CENTROIDAL Q:我现在在分析 ABAQUS EXAMPLE PROBLEM MANUAL 的 1.1.7 例子,但是当把 inp 文件导入时 出现这个问题: WARNING: The following keywords/parameters are not yet supported by the input file reader: *ELFILE *ELPRINT *INITIALCONDITIONS, TYPE=HARDENING *NODEFILE *NODEPRINT 为什么硬化初始...
即可正常安装. 9.软件的运行 由于配置license服务时,已设置为开机时启动license服务,即软件使用时只需要打开就可 以运行了. 打开软件的方式: 其一:程序组中"Abaqus6.10-1"选"ABaqusCAE"即可启动; 其二:如果在程序组中找不到该软件的启动快捷方式,可以用如下方式启动: 打开软件的安装文件夹,搜索"abq6101.bat",...
The Associative Interfaces enablegeometry transferfrom a CAD system to Abaqus/CAE. These powerful add-ons enable you to send selected components or an entire assembly from the CAD system to Abaqus/CAE with a single mouse click. You can modify your model in supported CAD systems and update the ...
The default precision version of Abaqus/Explicit to run if you do not specify the precision version on theabaquscommand line. Possible values areEXPLICIT(only the Abaqus/Explicit analysis is run in double precision) orBOTH(both the Abaqus/Explicit packager and analysis are run in double precision...
306 // Not there. Save at the next location307 setId = elsetMap_.size();308 elsetMap_.set(setName, setId);309 310 return setId;311}312 313 314Foam::label315Foam::fileFormats::ABAQUSCore::readHelper::readPoints316(317 ISstream& is...