Use this information to help you map a location code to a position on the unit. The following diagrams show field replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables. Rack views Figure 1. Rack front view ...
You can cross-reference a disk drive physical location code to the address. Use the address to find the location for the system, and then go to8202-E4C, 8202-E4D, 8205-E6C, or 8205-E6Dto find additional location information. Table 1. IOA and device address information runningIBM® i ...
Location Code : U78AA.001.WZSJ2DY-P1-C12 Voltage regulator 从故障关联位置初步判段,由于稳压器(P1-C12)故障。重启后导致(P1-C14)报错,可能是误报,但是安全起见,一起都换掉,更换步骤跟换VRM雷同,步骤如下: 二、故障处理1.1.先决条件 1.2.准备项 1.3.操作步骤 1.4.验证 (1)、power on系统,并active lp...
Servers (system unit and expansion units) use physical location codes to provide mapping of replaceable units. Location codes are produced by the server's firmware, which positions them so that they can be used to identify specific parts in a system. The location code format is the same for ...
Figure 1. Rear view of the 8202-E4B and 8205-E6B systems with PCI slots location codes Figure 2. PCI slots location codes in the 8202-E4B and the 8205-E6B systems Figure 3. PCI riser expansion with location codes in the 8202-E4B and 8205-E6B systems Table 1. PCI slot loca...
Note: Record the location of each disk drive you remove so that the disk drive can be replaced in the same location again. Unlock the disk drive handle (A) and pull it toward you to unseat the disk drive. Place one hand under the disk drive and carefully pull the drive out of the ...
Figure 1. Example display of device concurrent maintenance If the physical location does not appear in the Device Concurrent Maintenance display, perform the following steps: Find the feature code (FC) and sequence number (SN or SEQ) on the label that appears on the front of the system unit ...
The physical location code for the base system board is Un-P1. Table 1. SAS subsystem configurations for the 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D system SAS subsystem configurationRAID cache enablement card External SAS componentsSAS port cablesSAS cablesLimitations SAS base...
When a missing device is selected for processing, the missing resource menu checks several items. It checks whether the device is turned off, removed from the system, moved to a different physical location, or if it is still present.
Manually record the values of enclosure location, feature code/sequence number, enclosure serial number, and reserved. Record any service processor settings that you might have set using the operating system commands. Stop the system or logical partition.For instructions, seeStopping a system or logic...