Use this information to help you map a location code to a position on the unit. The following diagrams show field replaceable unit (FRU) layouts in the system. Use these diagrams with the following tables. Rack views Figure 1. Rack front view ...
Servers (system unit and expansion units) use physical location codes to provide mapping of replaceable units. Location codes are produced by the server's firmware, which positions them so that they can be used to identify specific parts in a system. The location code format is the same for ...
根据ERR信息,由最早故障时间定位,所触及到的硬件为: Location Code : U78AA.001.WZSJ2DY-P1-C12 Voltage regulator 从故障关联位置初步判段,由于稳压器(P1-C12)故障。重启后导致(P1-C14)报错,可能是误报,但是安全起见,一起都换掉,更换步骤跟换VRM雷同,步骤如下: 二、故障处理1.1.先决条件 1.2.准备项 1.3....
Note:The feature code number for the8202-E4B,8202-E4C,8202-E4D,8205-E6B,8205-E6C, or8205-E6Dis 78AA-001. For systems with a Host Ethernet adapter (HEA), check and record the server HEA device settings. For HMC: Expand theSystems Managementfolder in the navigation tree pane. ...
Figure 4 shows the PCI slots and their location codes for 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D systems. The 8202-E4C, 8202-E4D, 8205-E6C, and 8205-E6D systems have five PCIe x8 G2 full-height half-length slots and one PCIe x4 full-height half-length slot. All slo...
Attention:If you are servicing a failing part, see the service procedures forRemoving and replacing the 8202-E4B, 8202-E4C, 8202-E4D, 8205-E6B, 8205-E6C, or 8205-E6D Slimline media device with the system power on in IBM i. The following procedure is intended for installing a new or up...
The physical location code for the base system board is Un-P1. Table 1. SAS subsystem configurations for the 8231-E1C, 8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D system SAS subsystem configurationRAID cache enablement card External SAS componentsSAS port cablesSAS cablesLimitations SAS base...
If the computer room is below ground level, provide adequate drainage. Safety consideration and fire prevention Safety is a vital factor when planning computer installation. This consideration is reflected in the choice of the computer location, building materials used, fire prevention equipment, air ...
The combination identify and fault LED (amber color) shows the location of a field replaceable unit (FRU). When removing a FRU, first verify whether you are working on the correct FRU by using the identify function in the management console or other user interface. When removing a FRU by ...
Push down on the fan until it locks into place. Tilt the fan cage up and tighten the two fan cage screws(C)by turning in the clockwise direction. Figure 1. Replacing the fan in a rack-mounted model for8202-E4B,8202-E4C,8202-E4D,8205-E6B,8205-E6C, or8205-E6D...