If the location code ends with-Txx-Lxx, the server's firmware could not identify the physical location. When a physical location cannot be identified, a logical location code is provided. Where logical location codes occur in enclosures, the locations topic for the enclosure has the known conver...
Figure 1. Slot location for the RAID enablement card (P1-C13) Press the tab and slide the card out of the system as shown in the following figures. The RAID enablement card is attached to a plastic plate. You must slide the plastic plate out of the system to remove the RAID enablement...
30 self.pos_lng = 0 #location from tencent map 31 self.pos_lat = 0 32 self.i = 0 33 self.mess = "" 34 self.timer = "" 35 self.station = [(30.467499,114.408628),(30.47469,114.409661),\ 36 (30.489422,114.411117),(30.492301,114.411407),\ 37 (30.496725,114.416175),(30.4...
Figure 1. Rear view of the 8202-E4B and 8205-E6B systems with PCI slots location codes Figure 2. PCI slots location codes in the 8202-E4B and the 8205-E6B systems Figure 3. PCI riser expansion with location codes in the 8202-E4B and 8205-E6B systems Table 1. PCI slot locati...
Manually record the values of enclosure location, feature code/sequence number, enclosure serial number, and reserved. Record any service processor settings that you might have set using the operating system commands. Stop the system or logical partition.For instructions, seeStopping a system or logic...
Figure 1. Example display of device concurrent maintenance If the physical location does not appear in the Device Concurrent Maintenance display, perform the following steps: Find the feature code (FC) and sequence number (SN or SEQ) on the label that appears on the front of the system unit ...
The C1 slot must contain the system power control network (SPCN) card, and the C8 slot must contain the card with two 12X double data rate (DDR) cable ports. Note:Installing the 12X DDR cable ports at this location causes both the C8 and C6 slot space to be occupied. ...
The 146.8 GB U320 15,000 rpm 80–pin SCSI disk drive might be failing. Use the following table to determine the part number for the field replaceable unit (FRU). CCIN or FFC Type and model Part number Description Location code 2654 Any 03N5285 or 03N6350 146.8 GB U320 15,000 rpm ...
CCIN or FFC Type and model Part number Description Location code 2535 Any 03N5444 4-port 10/100/1000 base-TX Ethernet PCI-X adapter If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Selec...
If you are working with a RIO/HSL/12X loop number, seeConverting the loop number to 12X port location labelsto determine the starting ports for the RIO/HSL/12X loop with the failed link.This ends the procedure.