The described method can be used to create the anode of powerful x-ray tubes for medical purposes, in particular, a computer tomograph (CT). The thermal properties of the graphite base and the deposited tungsten coating, as well as the strength of the resulting coating were studied. Thermal ...
Schild., New X-Ray Tube Performance in Computed Tomography by Introducing the Rotating Envelope Tube Technology, Medical Physics 31, 2699 (2004).Schardt P, Deuringer J, Freudenberger J, Hell E, Knuepfer W, Mattern D, Schild M (2004) New X-ray tube performance in computed tomography by ...
X-ray cone-beam Computed Tomography is a powerful tool for the non-destructive investigation of the inner structure of works of art. With regard to Cultura... MP Morigi,C Labanti,N Scianna - 《Proc Spie》 被引量: 4发表: 2007年 加载更多研究点推荐 X-ray tube ...
In contrast to conventional attenuation-based X-ray imaging, grating-based phase contrast computed tomography (GBPC-CT) is a phase contrast micro-CT imaging technique that can provide high soft tissue contrast at high spatial resolution. While there is a variety of different phase contrast imaging ...
X-ray Computed Tomography (X-CT) is a 3D imaging technique based on the use of an X-ray beam source (either monochromatic or polychromatic) and of a 2D matrix-detector. The sample is mounted on a rotating stage, in order to acquire 2D projections of the X-ray linear attenuation coeffici...
Comparison of simulated and measured spectra of an industrial 450 kV X-ray tube An accurate knowledge of the X-ray source spectrum is required in order to optimize X-ray Computed Tomography systems. A simulation model based on the Mont... A Miceli,R Thierry,M Bettuzzi,... - 《Nuclear In...
In this case, they will raise the x-ray tube output and be therefore counterproductive. Protective gloves can only protect the hands when they are kept outside the sensor area, or even safer, outside the beam. 7.11.6.4.7 Occupational dose assessment The effective dose, E, can be estimated...
It comprises three major hardware components: (i) an X-ray tube to produce ultrashort-pulsed X-rays for the XA signal generation, (ii) a low noise ultrasound detector and (iii) a signal processing and data acquisition system. The X-ray generator (XRS-3, Golden Engineering Inc., IN, ...
Individual selection of X-ray tube settings in computed tomography coronary angiography: Reliability of an automated software algorithm to maintain constant image qualityIndividual selection of X-ray tube settings in computed tomography coronary angiography: Reliability of an automated software algorithm to ...
X-ray micro computed tomograph consist of a microfocus X-ray tube, a sample manipulator and a detector. All these components deve... E Grachev,E Kozlov,A Trubitsyn 被引量: 0发表: 2019年 Method for exchanging detector modules in an X-ray detector in a computed tomograph A method is ...