1、打开Schematic。 2、根据提示的模块去找,比如说我的报错。 [Opt 31-67] Problem: A LUT3 cell in the design is missing a connection on input pin I1, which is used by the LUT equation. This pin has either been left unconnected in the design or the connection was removed due to the tr...
AAA模块是以edf网表的形式提供给我们,由我们在工程里做集成,模块关系如下图所示: 将AAA模块所有的信号连接好以后,在imp阶段就报错了,出现了Opt 31-67错误。[Opt 31-67] Problem: A LUT6 cell in the design is missing a connection on input pin I5, which is used by the LUT equation. This pin has...
[Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I0, which is used by the LUT equation. This pin has either been left unconnected in the design or the connection was removed due to the trimming of unused logic. The LUT cell name is: Inst_XAUI_...
转:VivadoIP报[Opt31-67]错误问题解决⽅法 使⽤VIVADO编译代码时,其中⼀个IP报错,错误类似为 Implementation Opt Design [Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I0, which is used by the LUT equation. This pin has either been left unconnected...
LLVM Opt-Pipeline 查看 最近Compiler Explorer 支持了显示 LLVM Opt Pipeline Output 的能力,对于我们理解一个函数经历了哪些 pass 的细节非常有帮助。简单推荐一下这个工具。 1、Opt Pipeline优化是可选的选项… 左沙 scikit-opt发布重要更新(0.6.2),支持加速黑魔法 scikit-opt 是一个封装了7种启发式算法的 Python...
5. [Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I0, which is used by the LUT equation. This pin has either been left unconnected in the design or the connection was removed due to the trimming of unused logic. The LUT cell name is: logic_...
[Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I1, which is used by the LUT equation. This pin has either been left unconnected in the design or the connection was removed due to the trimming of unused logic. The LUT cell name is: sub_inst/...
The error below during opt_design is observed with QDMA Subsystem for PCI Express IP core design in Vivado version 2023.1 with UltraScale+ devices. ERROR: [Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I0, which is used by the LUT equation. This...
70111 - Vivado 2017.3 - [Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I0 Description Migrating a Vivado design from 2017.2 to 2017.3 results in the following error: [Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on inpu...
Opt Design [Opt 31-67] Problem: A LUT2 cell in the design is missing a connection on input pin I0, which is used by the LUT equation. This pin has either been left unconnected in the design or the connection was removed due to the trimming of unused logic. The LUT cell name is:...