执行undo port m-lag virtual-ip命令时,如果未指定ipv4-address参数,则表示删除接口下所有M-LAG虚拟IPv4地址。 当peer-link接口故障时,配置为standby的虚拟IPv4地址在角色为Primary的M-LAG设备上转为可用状态。如果配置为standby的虚拟IPv4地址未指定虚拟MAC地址,则使用接口的MAC地址作为虚拟MAC地址。此时,与M-LAG设备...
Cause 1:M-LAG member interfaces with the same M-LAG ID on both M-LAG devices changes to Up. Cause 2:M-LAG member interfaces have non-dual-homing configurations. For example, the DFS peer status changed to Down, or only one M-LAG device has the M-LAG ID. Procedure The trap mess...
When a QSFP+ to QSFP+ high-speed cable is installed on the port, the cable can only be used as a stack cable or a cable that connects peer-link interfaces in an M-LAG. Functions and Features Table 7-594 Functions and features of the CEL24LQFD-GK Functions and Fea...
To ensure correct user data processing, follow these guidelines when you configure the peer aggregate interfaces on each remote access device connected to the M-LAG interfaces: · If the M-LAG system uses distributed local mode for user authentication, ...
D. VRRP work with vPC as long as vPC peer-gateway is configured to address non-standard replies to the physical MAC address 免费查看参考答案及解析 题目: 配置EFS单板的PORT端口属性时,共有()种属性。如果将端口属性设置为“tag aware”,表示的含义为...
D. VRRP work with vPC as long as vPC peer-gateway is configured to address non-standard replies to the physical MAC address 免费查看参考答案及解析 题目: 配置EFS单板的PORT端口属性时,共有()种属性。如果将端口属性设置为“tag aware”,表示的含义为...
Fallback mode allows an active LACP interface to maintain a LAG without receiving PDUs from its peer. The fallback timer specifies the period the LAG waits to receive a peer PDU. Upon timer expiry, the port channel reverts to its configured fallback mode if one is configured. Static fall...
- Vlan is allowed on the peer link - we don't use MST - in the primary switch : show port-channel summary | inc Po106106 Po106(SU) Eth LACP Eth1/9(P) === show spanning-tree vlan 4008 VLAN4008Spanning tree enabled protocol rstpRoot ID Priority 36776Address 0023.04ee.be65This...
Po100 Desg FWD 1 128.4195 (vPC peer-link) Network P2pPo106 Desg FWD 1 128.4201 (vPC) P2pPo107 Desg FWD 1 128.4202 (vPC) Edge P2pEth1/57 Desg FWD 4 128.225 Edge P2pEth1/58 Desg FWD 4 128.229 Edge P2p in the secondary switch the PO doesn't appear on spanning-tree because i shut...
device # show external-port-link External-Port Link: Name Port or Port Channel Name App Name Description --- --- --- --- Ethernet11_ftd Ethernet1/1 ftd Ethernet16_ftd Ethernet1/6 ftd PC15_ftd Port-channel15 ftd FP4110-7-A# scope eth-uplink FP4110-7-A /eth-uplink # ...