仿真的话,如果是用Vivado2016.02的话联调Modelsim10.4,用Vivado2017.02的话联调Modelsim10.5,只要编译的库没有问题,那么设置Modelsim仿真时长为150us(user_link_up拉高)就能看到完整的PIO流程。 二.进阶 单次PIO操作只能搬运32bit,效率低,而且还会占用CPU总线权,所以我们要使用DMA模式,最开始接触到的是Xilinx官网给的一...
IP as the root port for my design, is there any signal in the PCIe hard IP to get to know the PCIe Link Up is done because in some other vendors we will get one output signal named "user_lnk_up" signal that will identify that the PCIe Express core is linked up with a host ...
ADDRCONF(NETDEV_UP): eth1: link is not ready PHY: 0:02 - Link is Up - 100/Full ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready eth0: no IPv6 routers present eth1: no IPv6 routers present root@luhao:~# 求助...我的PCIE网卡是RTL8111C的。 请参考:http://processors.wiki.ti.co...
如果设置 enable_sris_elastic_buffer_mode=1,log 提示能 link up 能起来,但是只有PL link up 成功,DL link up没起来。LTSSM 也能走到 L0,但是 DUT 发给 VIP INIT_FC1_* 后 VIP 不回任何 INIT_FC 相关,DUT 就一直发INIT_FC1,整个卡死了。 如果设置 enable_sris_elastic_buffer_mode=0,log 提示能 ...
2024款的ThinkBook 14+和16+较之家族前辈有了较大变化,除了升级酷睿Ultra平台以外,它们在标配OucLink接口的前提下,还都保留了2个2280标准的M.2硬盘位,其中16+还是双内存插槽设计,扩展潜力比游戏本更出色。其中,14+最高可选RTX 4050或4060独显,双烤功耗从上代60W提升到了95W,小钢炮实至名归。16+的独显版双烤...
2. User Guides and Reference Designs 3. IP Integration 4. Training Courses and Videos 5. Debug 6. Additional Resources The PCI Express (PCIe*) IP support center provides information about how to select, design, and implement PCIe links. There are also guidelines on how to b...
Read the P-Tile Avalon® Streaming Intel® FPGA IP for PCIe design example user guide › P-Tile Link Up Video Watch the demo of Stratix® 10 DX device featuring P-Tile link up with Intel® Xeon server. Standards & Specifications Compliance ...
The PCIe link is faulty. Procedure Restart the server and open the BIOS Device Manager in UEFI mode. On the Driver Health screen, select Repair the whole platform, and press Enter. Then, check whether the alarm is cleared. For details, see Troubleshooting ...
Enter thelspcicommand on the root port system to verify that the PCIe link is up. The console output should include a message like,PCIe device with vendor id: 0x10de and device id: 0x2296. Bring up both interfaces to establish an Ethernet link between the systems and assign the interfaces...
LinkUp Rate: 20 Base lid: 69 LMC: 0 SM lid: 2 Capability mask: 0x02510a68 Port GUID: 0x001b00000ca72621 22 Sun Dual Port 4x DDR IB Host Channel Adapter PCIe User's Guide • January 2008 You can also verify that the InfiniBand fabric is operational by entering the ibnetdiscover com...