Methods and devices for measuring full or partial Mueller matrix information in a single shot are described. One single shot polarimeter includes a polarization filter that is positioned to receive collimated light from a light source and to produce light having different polarization states. The ...
The polarization states of the input and output fields are measured using a commercial polarimeter. An excellent agreement is found between experimental and theoretical Mueller matrices.doi:10.1016/j.optlaseng.2019.05.030J. Carlos Gonzalez De Sande...
The design and operation of a Mueller matrix imaging polarimeter is presented. The instrument is configurable to make a wide variety of polarimetric measurements of optical systems and samples. In one configuration, it measures the polarization properties of a set of ray paths through a sample. The...
图2 双旋转波片测量系统原理图Fig.2 Schematic diagram of dual-rotating-retarder Mueller matrix polarimeter 系统选取起偏棱镜PL1的起偏方向为Q方向,依次将PL2的透过轴及WP1,WP2的快轴对准至Q方向,并对WP1,WP2的延迟量进行拟合[15-16],得出δ1,δ2分别为87.6°和88.4°。 在建立图2的测量系统时,选择激光...
Systematic errors specific to a snapshot Mueller matrix polarimeter. Appl. Opt. 48, 1135–1142 (2009). Article ADS Google Scholar Le Gratiet, A., Rivet, S., Dubreuil, M. & Le Grand, Y. 100kHz-Mueller polarimeter in reflection configuration. Opt. Lett. 40, 645–648 (2015). Article...
C. Optimum angles for a Mueller matrix polarimeter. Proc. SPIE 2265, 314–326 (1994). Article ADS Google Scholar Wood, T. C. & Elson, D. S. Polarization response measurement and simulation of rigid endoscopes. Biomed. Opt. Express 1, 463–470 (2010). Article PubMed PubMed Central ...
Goldstein, Applied Optics,1992 First, the polarimeter is operated with no sample and Fourier coefficients obtained from the measured modulated intensity. Second, using error-compensation equations with matrix elements of the identity matrix inserted for the Mueller matrix elements, calculate the errors ...
Time-sequential Mueller polarimeter, that allows measuring Mueller matrix elements images by using three- and four- input polarizations methods, is discussed. Mueller matrix measurement errors for different test anisotropic media are examined. The comparison between experimental and theoretical estimations of...
I perform an optimization of this polarimeter c... MH Smith - 《Appl Opt》 被引量: 190发表: 2002年 Optimizing a dual-rotating-retarder Mueller matrix polarimeter An optimization of a dual-rotating-retarder Mueller matrix polarimeter is performed by minimizing the condition number of the system ...
Symmetry relations for the Mueller scattering matrix integrated over the azimuthal angle J Quant Spectrosc Radiat Transfer (2013) T.K.Muet al. Static hyperspectral imaging polarimeter for full linear Stokes parameters Opt Express (2012) T.K.Muet al. ...