按照MMWAVE-STUDIO-CASCADE user guide 上的指导来操作,在进行过Inter-channel mismatch calibration之后,还未进行Phase Shifter Calibration的情况下,使用默认Phase Shifter Calibration文件配置,进行场景的数据采集和处理工作,首先用MMWAVE STUDIO跑Cascade_Configuration_TXBF.lua和Cascade_Capture.lua脚本文件,再transfer files...
请参考docs目录下的mmwave_studio_cascade_user_guide.pdf,级联板是只有两个串口,再使用mmwave studio过程中,串口并不需要。 向上 0 True 向下 bo yang99 4 年多前 回复Chris Meng Expert 1385 points 一个是FTDI接口 一个是RS232的串口。 请问只用FTDI口 就能链接mm 是吗? 另外 我FTDI在mm 中已经...
Other Parts Discussed in Thread:AWR2243,AWR1243,MMWCAS-DSP-EVM, ,MMWAVE-DFP,MMWAVE-STUDIO Hi, I am trying to connect to the radar through USB & Ethernet. I am following the mmWave Studio Cascade user guide Once I try to instal the MetaImage file, following points...
Answer:In new version of mmWave Studio we are providing DCA1000-CLI tool (<mmwave_studio_02_01_00_00>\mmWaveStudio\PostProc\DCA1000EVM_CLI_Control.exe) and its source code which can be used for this purpose. Follow the documentation mmwave_sdk_user_guide.pdf (section 3.3....
MIMO Radar Configurations http://www.ti.com/cn/lit/pdf/swra554 System Performance Measurement with AR12xx Device http://www.ti.com/cn/lit/pdf/swra549AWR1243 Cascade http://www.ti.com/cn/lit/pdf/swra574 AWR1xxx Power Management Optimizations- Low Cost LC Filter Solution http://www.ti...
https://software-dl.ti.com/ra-processors/esd/MMWAVE-STUDIO/latest/exports/mmwave_studio_cascade_user_guide.pdf Wei Jiang 说: 而MMWAVE-STUDIO-2G里面也就是3.0.0.14版本中也没有 Wei Jiang 说: 请问是否是因为SDK已经整合到其他软件中例如MMWAVE-Stuido。
不知道是什么原因导致的,网线也是原装的,没有松动,试了好多次都不行。之前使用12V的充电宝 成功过。 请按照mmwave_studio_cascade_user_guide.pdf里13. Troubleshooting Not able to connect TDA2XX from mmWaveStudio over the network检查一下配置。
The configuration for this use case is described in the Cascade User Guide included in the latest MMWAVE STUDIO release. MMWAVE STUDIO uses LUA scripting language. LUA examples are included for single-device, multi-device MIMO and multi-device TX-beamforming configurations. ...
for raw data capture, you can not use radar studio GUI any more. You can flash the OOB demo binary (or connnect CCS) and run in the demo mode. Then running DCA1000 CLI command in a cmd window to control DCA1000, please see mmwave_studio_user_guide.pdf section 3.1 for the ...
6 Software Files The cascade board was configured using an updated version of the MMWAVE-STUDIO tools. 7 Related Documentation 1. Texas Instruments, Programming Chirp Parameters in TI Radar Devices Application Report 2. Texas Instruments, AWR2243 76-GHz to 81-GHz High-Performance Automotive MMIC 3...