Magnetic 24VDC brake Always turn the input power OFF when an alarm occurs. If an alarm occurs, remove the cause, and secure the safety before resetting the alarm. Never go near the machine after restoring the power after a power failure, as the machine could start suddenly. (Design the ...
However, when using MDS-C1/CH-V2 (drive unit with 2 axes), both axes are controlled at the same time with the larger setting value of these 2 parameters. POINT 2. This control will not function if an alarm for which dynamic brakes are set as the stopping method occurs in an axis ...
Alarm 246 15.2.3 Operation Stop Cause 247 15.2.4 Emergency Stop Cause 247 15.2.5 Temperature Detection 248 15.3 Protection 249 15.3.1 Stroke End (Over Travel) 249 15.3.2 Stored Stroke Limit 249 15.3.2.1 Stored Stroke Limit I/II 250 15.3.2.2 Stored Stroke Limit IB 252 15.3.2.3 Stored ...
MTB: Machine tool builder Also refer to the manuals on "Manual List" as necessary. (Caution) - The version numbers are current as of the editing of this manual, but may be updated in the future. - GX Developer Version 8 (Model SW8D5C-GPPW) is the new name of the old "Windows ...
2. Items related to faults and abnormalities If the battery low alarm is output, save the machining programs, tool data and parameters to an input/output device, and then replace the battery. If the BATTERY alarm occurs, the machining programs, tool data and parameters may be damaged. After...
- Servo stop method: Dynamic stop - Spindle stop method: Coast to a stop [Detector alarm (Servo drive unit)] - MDS-B-HR() Scale not connected - AT343, AT543, AT545(Mitsutoyo) CPU error - LC193M, LC493M, LC195M, LC495M, RCN223M, RCN227M, RCN727M, RCN827M, EIB Series(...
MITSUBISHI三菱M800M80E80C80 Series Specifications Manual (Hardware)用户手册.pdf,Introduction This manual describes the specifications of Mitsubishi Electric CNC. Supported models are as follows: Supported models Abbreviations in this manual M800W Series
Also refer to the manuals on Manual List as necessary. Manual List Manuals related to M800/M80/E80/C80 Series are listed as follows. These manuals are written on the assumption that all optional functions are added to the targeted model. Some functions or screens may not be available ...
Items related to battery If the battery voltage drop warning alarm occurs, save the programs, tool data and parameters with the input/output device before exchanging batteries. Do not short-circuit, charge, overheat, incinerate or disassemble the battery. Dispose the spent battery according the ...
If a command is issued with two addresses which do not match the plane, an alarm will occur. (Note 2) The axes configuring a plane can be designated by parameters. Refer to the section entitled "Plane Selection". 17 3. Positioning/Interpolation 3.2 Linear/Circular Interpolation (2) R-...