A和B之间已放通vlan 4051 设备A 目的 mirroring-group 1 remote-destination mirroring-group 1 remote-probe vlan 4051 设备B 源 mirroring-group 1 remote-source mirroring-group 1 remote-probe vlan 4051 interface Bridge
kubectl create mirroringgroup 1 ``` 这条命令用于在K8S集群中创建一个名称为1的mirroring group,该mirroring group将用于定义流量镜像的规则。 2. 将监控端口加入到mirroring group 1中: ```bash kubectl addport monitor-port mirroring-group1 ``` 这条命令用于将名为monitor-port的监控端口加入到之前创建的mirr...
Mirroring group 1: Type: Local Status: Active Mirroring port:Ten-GigabitEthernet2/0/0Inbound Monitor port:Ten-GigabitEthernet2/0/1 Table 1Command output Field Description Mirroring group Number of the mirroring group. Type Type of the mirroring group. Only ...
port link-type access port access vlan 299 mirroring-group 2 monitor-port undo stp enable interface bridge-aggra x port trunk permit vlan 299 源交换机 vlan 299 undo mac-address mac-learning enable mirroring-group 1 remote-source mirroring-group 1 mirroring-port g1/0/x both mirroring-group 1...
一、定义mirroring group system-viewmirroring-group 2 #group_id 二、定义被镜像的端口,也就是源端口 mirroring-group 2 mirroring-port eth 1/0/4 both 其中both指的是从该端口进来和出去的数据包都将被捕获,还可以选择inbound和outbound 三、定义目的端口 mirroring-group 2 monitor-port eth 1...
Monitor port: HundredGigE1/0/2 Mirroring group 2: Type: Local Status: Active Mirroring port: HundredGigE1/0/5 Inbound Monitor port: HundredGigE1/0/6 Encapsulation: Destination IP address 1.1.1.1 Source IP address 2.2.2.2 DSCP 1 VLAN 2 VRF Instance 3 Dest...
show monitor session summaryPort MirroringPort mirroring enables data plane monitoring functionality which allows the user to send an entire traffic stream for testing. Port mirroring sends a copy of packets of a port’s traffic stream, called “mirrored port”, into an analyzer port. Port mirrorin...
The server (a data monitoring device) that has the monitoring software installed connects to Ethernet2/0/2 on the router to analyze the captured packets. To ensure enterprise information security, configure local port mirroring on the router to help the server monitor ...
The server directly connects to GigabitEthernet0/0/2 on SwitchA. The server (monitoring device) is required to monitor packets with the 802.1p priority of 6 sent by HostA. Figure 10-7 Networking of local flow mirroring Configuration Roadmap The configuration roadmap is as ...
Remote Switch Port Analyzer (RSPAN)Allows you to monitor network traffic from source ports distributed over multiple physical switches. RSPAN copies the source traffic into a special RSPAN configured VLAN. This VLAN needs to be trunked to the other switches involved. RSPAN works at Layer 2. ...