nuclear energy level transitionsnuclear isomerismnuclei with mass number 150 to 189/ gamma-decayK-forbidden transitionsisomer conversion coefficientinternal conversion coefficientbeta-decayHigh-precision measurements of the relative intensities of KX - and γ-rays associated with the decay of the isomer ...
High-energy neutrons have been detected using a specially designed setup placed on a cold neutron beam extracted from the ORPHEE reactor in Saclay. The 146±19 b inelastic neutron acceleration cross section in the ORPHEE cold neutron flux confirms the high cross section for this process on the ...
In brief, the planar acquisition of post-therapy whole-body scans (PTxWBS) was performed by using a dual-headed gamma camera (Discovery NM/CT 670; GE). The camera was equipped with a high-energy general-purpose pa...
Polyphosphonate ligands labelled with radioisotopes decaying by moderate energy beta emission have shown utility as palliative agents for painful bone meta... S Chakraborty,T Das,PR Unni,... - 《Nuclear Medicine Communications》 被引量: 88发表: 2002年 Lutetium-177-EDTMP for bone pain palliation...
The International Atomic Energy Agency (IAEA) reports the thermal neutron capture cross section (σ) as 2.8 b and a resonance integral (Io) of 4.7 b for 177mLu production (L176u(n,γ)L177mu)(International Atomic Energy Agency, 2015), this value is also supported by Roig, Bélier et a...
such as67Cu or90Y (which has the additional advantage of a higher b-particle energy) may increase exposure as compared with177Lu or225Ac. Further studies using these radionuclides would be beneficial. 本研究的主要局限性...
1). 177Lu is a favorable isotope for theranostic application with a half-life of 6.7 days, a maximal tissue penetration of 2 mm, and a low energy emission (Eβ-max 0.49) that causes damage to neighboring healthy cells. 177Lu emits 2 photons at 113 KeV (6.4%) and 208 Kev (11...
High-energy neutrons have been detected using a specially designed setup placed on a cold neutron beam extracted from the ORPHEE reactor in Saclay. The 146±19 b inelastic neutron acceleration cross section in the ORPHEE cold neutron flux confirms the high cross section for this process on the ...
This work aims to validate a customized GEANT4 model of our HPGe system in Marinelli beaker geometry to propose an operational approach properly quantifying Lu-177 and (177)mLu in waste samples. The system's efficiency curve was calculated by modelling gamma sources in the energy range of ...
Dracoulis GD.Kondev FG.Lane GJ.Byrne AR.Kibedi T.Ahmad I. Carpenter MP.Freeman SJ.Janssens RVF.Hammond NJ.Lauritsen T. Lister CJ.Mukherjee G.Seweryniak D.Chowdhury P.Tandel SK.Gramer R.Physics Letters, B. Nuclear Physics and High Energy Physics...