该报警的原因是由于B轴伺服电机内置脉冲编码器通信异常。1、断电后检查并重新插接B轴伺服放大器相关电缆后试机;2、如果故障依旧,因此推测是由于脉冲编码器故障;3、替换脉冲编码器后安装试机。如显示“EX2561 SERVOBATTERY ABNORMAL;306 APC ALARM: AXIS BATTERY VOLT-AGE 0(B);300 APC ALARM: AXIS NEED ...
电池没有电或者你断开过编码器线造成的原点丢失,手动摇到个轴的原点位置,然后改1815APZ,把0改为1关机重启就可以了
APC alarm:nth-axis communication n轴(1~4轴)APC通讯错。(数据传送异常)。 APC、电缆或伺服接口模块不良。 302 APC alarm:nth-axis over time n轴(1~4轴)超时错。(数据传送异常)。 APC、电缆或伺服接口模块不良。 303 APC alarm:nth-axis framing n轴(1~4轴)APC成帧错。(数据传送异常)。 APC、电缆...
有关绝对编码器(APC)的报警 300 APC ALARM: n AXIS ORIGIN RETURN (第n轴需回零) 参考点丢失,需对第n轴(1~4 轴),进行参考点设定。请检查参数No.1815#4(APZ) 301 APC ALARM: n AXIS COMMUNITCATION ERROR (APC报警:第n轴通讯错误) 由于绝对位置检测器的通讯错误,机械位置未能正确求得。(数据传输异常...
设备断电停机几小时后再开机时,显示“306 APC ALARM: AXISBATTERY VOLTAGE 0(X);306 APC ALARM:AXIS BATTERYVOLTAGE 0(Y);306 APC ALARM:AXIS BATTERY VOLTAGE 0(Z);“300 APC ALARM: AXIS NEED ZRN (X);300 APC ALARMAXIS NEED ZRN (Y);300 APC ALARM: AXIS NEED ZRN (Z)”。这时切勿关断设备电源...
替换后安装试机,又显示“EX2561SERVOBATTERYABNORMAL;306APCALARM:AXISBATTERYVOLT-AGE0(B);300APCALARM:AXISNEEDZRN(B);307APCALARM:AXISBATTERYDOWNI(B);307APCALARM:AXISBAT-TERYDOWNI(V);307APCALARM:AXISBATTERYDOWNI(W)”报警。通电状态下,更换CNC和伺服系统后备电池后按“RESET”键可消除307报警,断电重启...
设备断电停机几小时后再开机时,显示“306APCALARM:AXISBATTERYVOLTAGE0(X);306APCALARM:AXISBATTERYVOLTAGE0(Y);306APCALARM:AXISBATTERYVOLTAGE0(Z);“300APCALARM:AXISNEEDZRN(X);300APCALARMAXISNEEDZRN(Y);300APCALARM:AXISNEEDZRN(Z)”。这时切勿关断设备电源,将NC后备电池(4节)更换后,按“RESET”键即可...
300 APC Alarm From Unplugged Motor What if you unplug your motor and get a 300 APC alarm? This means your machine has an absolute pulse coder. An incremental pulse coder requires that you reference the machine every time you turn the coder back on. This type of coder has a memory backup...
DGN. 300:用检测单位表示轴位置偏差量,计算公式如下: DGN. 301:用最小移动单位显示各轴距参考点的距离 说明:DGN.310、311为APC(绝对式脉冲编码器)的诊断数据。 PR1:变更以下参数:No.1821,1850,1860,1861 PR2:变更ATS(No.8302#1)参数 BZ1:检测APC电池电压为0V(感应同步器) ...
设备断电停机几小时后再开机时,显示“306 APC ALARM: AXISBATTERY VOLTAGE 0(X);306 APC ALARM:AXIS BATTERYVOLTAGE 0(Y);306 APC ALARM:AXIS BATTERY VOLTAGE 0(Z);“300 APC ALARM: AXIS NEED ZRN (X);300 APC ALARMAXIS NEED ZRN (Y); 300 APC ALARM: AXIS NEED ZRN (Z)”。这时切勿关断设备...