chargeStatusA = "bağlı değil" chargeStatusB = "bağlı" chargeStatusC = "dolduruyor" chargeStatusE = "elektrik yok" chargeStatusF = "hata" chargedEnergy = "Doldu" co2 = "Şebeke CO₂" configured = "Yapılandırıldı" controllable = "“Kontrol edilebilir”" c...
chargeStatus = "Status" chargeStatusA = "brez povezave" chargeStatusB = "povezan" chargeStatusC = "polnjenje" chargeStatusE = "brez moči" chargeStatusF = "napaka" chargedEnergy = "Napolnjeno" co2 = "CO₂ iz omrežja" configured = "Konfigurirano" controllable = "Nadzorljiv" cu...
labelResidualPower = "Potenza residua" title = "Controllo del comportamento" [config.deviceValue] broker = "Broker" bucket = "Bucket" capacity = "Capacità" chargeStatus = "Stato" chargeStatusA = "non connesso" chargeStatusB = "connesso" chargeStatusC = "in carica" chargeStatusE = "co...
[lp-1 ] DEBUG 2025/01/30 16:28:41 charger status: B [lp-1 ] DEBUG 2025/01/30 16:28:41 plan: charge 1h50m58s between 2025-01-31 02:09:02 +0100 CET until 2025-01-31 04:00:00 +0100 CET (power: 11040W, avg cost: 0.331) [lp-1 ] ERROR 2025/01/30 16:28:45 max charge...
[lp-1 ] DEBUG 2024/12/01 14:23:40 charge total import: 1177.337kWh [lp-1 ] DEBUG 2024/12/01 14:23:40 charger status: A Zendure lädt mit 1200W. Das passt doch: Power: -1161W Alles richtig. dann haut aber was mit der Darstellung irgendwie nicht hin. So sollte es sein: ...
[lp-1 ] DEBUG 2024/11/14 13:51:54 charger status: B [site ] DEBUG 2024/11/14 13:52:24 --- [lp-1 ] DEBUG 2024/11/14 13:52:25 charge power: 0W [lp-1 ] DEBUG 2024/11/14 13:52:25 charge currents: [0.3 0.2 0.1]A [site ] DEBUG 2024/11/14 13:52:25 pv power: 6676...
[lp-1 ] DEBUG 2025/03/08 10:20:15 charger status: A [site ] DEBUG 2025/03/08 10:20:15 solar forecast: accumulated 0.4kWh, produced 5.1kWh, scale 14.3 Richtige Auslesung: [lp-1 ] DEBUG 2025/03/08 10:19:54 charge power: 0W [site ] DEBUG 2025/03/08 10:19:54 grid power: ...
session: chargeRater.chargedEnergy=4.9 - chargedAtStartup=0.0 [lp-4 ] ERROR 2024/09/10 10:12:23 charge total import: timeout [lp-4 ] DEBUG 2024/09/10 10:12:23 charger status: B panic: runtime error: invalid memory address or nil pointer dereference [signal SIGSEGV: segmentation violat...
status notifications using Telegram, PushOver and many more logging using InfluxDB and Grafana granular charge power control down to mA steps with supported chargers (labeled by e.g. smartWB as OLC) REST and MQTT APIs for integration with home automation systems Add-ons for Home Assistant and...
[lp-1 ] DEBUG 2024/08/20 12:01:07 charger status: B Aug 20 12:01:07 raspberrypi evcc[637]: [lp-1 ] DEBUG 2024/08/20 12:01:07 charge start energy: 4.88e+03kWh Aug 20 12:01:07 raspberrypi evcc[637]: [lp-1 ] INFO 2024/08/20 12:01:07 car connected Aug 20 12:01:07 ...