charger#meter: charge # charge metermode:"pv"#default charge mode to apply when vehicle is disconnected; use "off" to disable by default if charger is publicly available#remaining settings are experts-only and best left at default valuespriority:4#relative priority for concurrent charging in PV ...
[lp-1 ] ERROR 2024/08/20 12:01:07 charge meter: not available Aug 20 12:01:07 raspberrypi evcc[637]: [lp-1 ] DEBUG 2024/08/20 12:01:07 charge total import: 4882.904kWh Aug 20 12:01:07 raspberrypi evcc[637]: [ocpp-1] WARN 2024/08/20 12:01:07 waiting for local ...
chargers: - name: Carport type: custom # or default status: # charger status A..F source: mqtt topic: carport/lp/1/ChargeStatus timeout: 10m enabled: # charger enabled state (true/false or 0/1) source: mqtt topic: carport/lp/1/ChargePointEnabled timeout: 10m enable: # set charger ...
-title:Garage#display name for UIcircuit:main#charger: wallbe # chargercharger:my_chargermode:"pv"#default charge mode to apply when vehicle is disconnected; use "off" to disable by default if charger is publicly available#meter: charge # charge meterphases:0#remaining settings are experts-onl...
*** meter: 1ESY1161231764 - name: pvgarten type: template template: tasmota usage: pv host: 192.168.6.65 - name: pvstrasse type: template template: tasmota usage: pv host: 192.168.6.16 chargers: - type: template template: alfen id: 1 host: 192.168.1.130 port: 502 modbus: tcpip name:...
c6ddc9bAdd meter Solarwatt Manager flex (#18561) 01faac1Add solar forecast using Solcast and Forecast.Solar (#18269) c3e7f59Bluelink: add climater (#18370) 8f8bc0eCLI: add database flag; improve systemd db check (#17993) 3936c13CLI: remove --database shortcut (#18427) ...
I want to charge between 30 % and 80 % when there is enough PV production to support the 2.4 kw charging (with 10 A * 240 V), which means when my production is higher than + 2.4 kw. For that purpose the S0 800 Imp/kWh meter is totally sufficient. My car has a mileage of ...
charge point connected, registering: A22A1445799 [ocpp ] ERROR 2025/03/08 13:16:04 ocpp message (6604): PropertyConstraintViolation - Field Call.Payload.MeterValue[0].SampledValue must be minimum 1, but was 0 for feature MeterValues ([2,"6604","MeterValues",{"connectorId":1,"meter...
So we need to find out why EVCC is not stopping the charge... to find out we need longer logs from evcc. HA is not as useful for logs as I have heard. The best option: install the system temporary on your PC, copy the YAML and read the logs from evcc. "Limit pojazdu jest poni...
[ocpp-1] DEBUG 2024/07/09 12:02:15 waiting for chargepoint: 5m0s [ocpp ] INFO 2024/07/09 12:02:19 charge point connected, registering: SN10052307203612 [ocpp ] TRACE 2024/07/09 12:02:19 sent SN10052307203612: [2,"2431342368","TriggerMessage",{"requestedMessage":"MeterValues","connec...