处理上实际上就是先物化(CTAS 到s3 中),然后基于双胞胎策略,写入一个view 到nessie 中,如下图,如果需要支持branch 就需要调整 双胞胎策略macro 了 参考解决方法 view 模式的 结合上边说的,直接修改view 物化定义就可以了,扩展下支持branch (commit 也是可以的), view 定义放到macro 中,dbt 有自己的macro 搜索顺...
处理上实际上就是先物化(CTAS 到s3 中),然后基于双胞胎策略,写入一个view 到nessie 中,如下图,如果需要支持branch 就需要调整 双胞胎策略macro 了 参考解决方法 view 模式的 结合上边说的,直接修改view 物化定义就可以了,扩展下支持branch (commit 也是可以的), view 定义放到macro 中,dbt 有自己的macro 搜索顺...
dbt should not callcreate_schema(...)in the beginning of the run. It should callcreate_schema(...)right before the model materialization happens and then pass the relation it's going to materialize as an argument to this macro. Schemas can be different for every model so creating the init...
dbt's ability to dynamically pick the correct materialization based on the active database target is calledmultiple dispatch. This feature unlocks a whole world of cross-database compatibility features -- if you're interested in this, please let us know on Slack!
I believe this is a new bug in dbt-core I have searched the existing issues, and I could not find an existing issue for this bug The env_var() function does not work in overrides of the create_schema macro is overridden. For example, after defining and using the macro like this......
It can also return converted system error codes using the HRESULT_FROM_WIN32 macro. Errors can originate from VDS itself or from the underlying VDS provider that is being used. Possible return values include the following. Táblázat kibontása Return code/valueDescription S_OK The partition ...
Il peut également retourner des codes d’erreur système convertis à l’aide de la macro HRESULT_FROM_WIN32 . Les erreurs peuvent provenir de VDS lui-même ou du fournisseur VDS sous-jacent utilisé. Les valeurs de retour possibles sont les suivantes. Agrandir le tableau Code/valeur de ...
It can also return converted system error codes using the HRESULT_FROM_WIN32 macro. Errors can originate from VDS itself or from the underlying VDS provider that is being used. Possible return values include the following. Proširi tabelu Return code/valueDescription S_OK The target was ...
This method can return standard HRESULT values, such as E_INVALIDARG or E_OUTOFMEMORY, andVDS-specific return values. It can also return convertedsystem error codesusing theHRESULT_FROM_WIN32macro. Errors can originate from VDS itself or from the underlyingVDS providerthat is being used....
{replica}', ts) ORDER BY id SETTINGS allow_nullable_key = 1 Query id: 66602f4e-d20a-40e7-8bf9-fb46ef9fa22b 0 rows in set. Elapsed: 0.004 sec. Received exception from server (version 23.4.1): Code: 36. DB::Exception: Received from localhost:9000. DB::Exception: Macro 'uuid' ...