ambari_version: '2.7.4.0' hdp_version: '3.1.4.0' hdf_version: '3.4.1.1' on CentOS Linux release 7.8.2003 (Core) However, when I'm trying to make some kafka configuration changes - I'm getting error message : Consistency Check Failed ...
C -- Configuration consistency check failed Peer-link interface: BAGG1 Peer-link interface state (cause): UP Keepalive link state (cause): UP M-LAG interface information M-LAG IF M-LAG group Local state (cause) Peer state Remaining down time(s) BAGG3 1 UP UP - [DeviceA] display m-...
Check whether user information is correct. 37 EAPOL connect check fail 802.1X entry consistency check failed. Contact technical support. 38 EAPOL nas error Failed to apply for timer resources. Authentication requests failed to be sent because the device queue was full. Contact technica...
Configuring M-LAG Consistency Check Context An M-LAG is composed of two devices that are virtualized into one device (a Layer 2 logical node), making the logical topology clear and requiring that certain configurations on the two devices must be consistent. If certain requirements are not ...
Check failed for reason: Twenty-FiveGigE1/0/13:2, Twenty-FiveGigE1/0/13:3 and Twenty-FiveGigE1/0/13:4 belong to a port group, Please shutdown all of them before changing the working mode. When you receive the message that requires you to shut down all ports in a port group, u...
switch#show consistency-checker stp-stateConsistency Checker Result for STP (VLAN CBL): FAILED STP/HW VLAN CBL mismatch (port Eth8/3): INGRESS FORWARDING: (STP) 1-10, (HW) 1-10,30-35 EGRESS FORWARDING: (STP) 1-10, (HW) 1-10,30-35 ...
Checks if any of the modules (linecard, fabric, and so on) reported diagnostic failures or in powered down / failed state show module show inventory show diagnostic result module all detail 10. PSU & FAN Health Check Detects if any of the power supplies is not in operational sta...
consistency in the configuration data. If the notification process is inhibited, or if the data is otherwise deleted or lost, follow the cleanup steps that are listed here to remove the configuration data. These changes are not recoverable unless you make a backup of the system state f...
Computer is making a beeping noise May see one or more of the following (or similar) errors Controller ID: 0 PD removed: --:--:2 Controller ID: 0 VD is now DEGRADED VD 1 Controller ID: 0 Consistency Check failed on VD: 1
VMware vSAN Issue/Introduction Symptoms: vSAN health check shows a warning of network diagnostic mode in the vSAN cluster configuration consistency check. The warning message is "This host diagnostic mode configuration is inconsistent with cluster configuration", click the "Remediate inconsistent configurati...