CONCLUSIONS: The automated RPR test showed overall lower sensitivity than the conventional RPR test based on the treponemal test, but higher seroconversion after treatment. The automated RPR test could be used t
We also propose that when S/CO of the CLIA or EIA is high enough, TPPA confirmation can be omitted from the testing algorithm, and costs would be significantly reduced. Introduction Syphilis, a sexually transmitted disease (STD) caused by Treponema pallidum subspecies pallidum (TP), is a ...
Automated testsSyphilisTreponemal testBackground Automated immunoassays (AI) for detection of T. pallidum antibodies are increasingly used for syphilis screening in the United States. These assays demonstrate fast performance, reduced labour requirements, and high throughput with walk-away capability. ...