Cadence allergo软件导入网表时提示提示#1 ERROR(24) File not found Packager files not found #2 ERROR(102) Run stopped because errors were detected 此时第一步检查allergo软件里面的封装库路径有没有设置对,为Setup→ user preferences editor → paths→ library→ 里面的padpath和psmpath。 如果确认路径设置...
1 ERROR(24) File not found Packager files not found 一个错误是没找到指定网表。你网表的路径指定在你原理图输出的一个文件夹***/allegro的文件夹,而且网表确定已经输出。
Packager files not found 6 r1 a# e* X1 @* p #2 ERROR(102) Run stopped because errors ...
这是一个比较简单的问题,看清楚,第一行写着“package files not found” 这就说明你在pcb editor中没有指定封装库的路径、或者没有指定正确。做法如下:点击set up->user preferences 就会打开一个对话框如图示。paths里面有两个选项要设置:一个是psm path 一个是pad path 第一个设置pcb封装的路...
Packager files not found #2 ERROR(102) Run stopped because errors were detected netrev run on...
WARNING(SPMHNI-194): Symbol '2POS_SPDT' for device 'SW SLIDE-SPDT_2POS_SPDT_2POS_SP' not found in PSMPATH or must be "dbdoctor"ed. I have checking my design path which seems to be correct and I am able to see the padstack P654C45P but still it doesnot read i...
1、有器件没有对应的PCB封装,这要查看你的库链接是否正确,PCB封装名是否填对,如果没有PCB封装,需要做库。你可以用文本编辑器打开env文件(路径在你home环境变量下的pcbenv文件夹下),检查以下这几行设置是否正确。set padpath = d:\lib\pad ;;注:这指的是设置你的焊盘库路径 set psmpath ...
Files are managed automatically by DDMS. 9/27/94 Cadence Design Systems, Inc. 2-44 Design Framework II 2-45 The Library Browser and Search Path Library Browser Set Library Search Path Displays libraries found in the specified search path Lets you expand cells and cellviews in the libraries ...
这个问题导致的原因是网络表位置的问题,如图所示,在最后的Import directory的路径要设置到capture生成网表,.net或者后面更名的.tel文件所在的位置,一般在schematic文件夹下allegro文件夹里面。以后谁碰到这个问题。如果再有问题可以私信我。