F端口:Fabric Port 光纤端口;一种交换连接端口,也就是两个N端口连接的"中间端口" NL端口:Node Loop Port 节点环路端口;通过它们的NL端口连接到其他端口,或通过一个单独的FL端口连接到交换后的光纤网络;或是NL端口连接到F端口到F端口到N端口(通过交换机) FL端口:Fabric Loop Port光纤环路
nocard该槽位没有连接任何卡nomodule该端口没有gbic模块nolight该端口没有收到光信号nosync收到光信号但是没有同步insync收到光信号并且正在同步铜口显示为sync光纤将显示为onlinelaserflt该模块收到激光错误gbic故障portflt端口已经标记为故障gbic光纤或设备故障diagflt端口自诊断故障gport或flport端口卡或主板故障online...
Brocade 光纤交换机常⽤命令 使⽤电脑连接管理⽹⼝,默认IP地址为:192.168.0.1,掩码:255.255.255.0 默认⽤户名:admin,默认密码password 1. switchStatusShow 查看交换机的总体健康状态 switch:admin> switchstatusshow Switch Health Report Switch Name: SWFCR IP address: 10.33.54.176 Switch...
7、 6 In_Sync portScn: 16 E_Port port generation number: 74portId: 660f00portIfId: fportWwn: 20:0f:00:05:1e:7b:e7:bfportWwn of device(s) connected:Distance: normalportSpeed: N1GbpsLE domain: 0FC Fastwrite: OFFInterrupts: 1724 Link_failure: 8 Frjt: 0 Unknown: 0 Loss_of_sync...
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err xx: 849.1k 493.2k 0 0 0 0 0 0 2.3m 0 4 6 0 0 0 0 0 0 Yleinen syy: Voimassa vain, jos satamatilastot on selvitetty viimeisen 24 tunnin aikana...
6 In_Sync portScn: 16 E_Port port generation number: 74portId: 660f00portIfId: fportWwn: 20:0f:00:05:1e:7b:e7:bfportWwn of device(s) connected:Distance: normalportSpeed: N1GbpsLE domain: 0FC Fastwrite: OFFInterrupts: 1724 Link_failure: 8 Frjt: 0 Unknown: 0 Loss_of_sync: 38...
3. 使用命令haShow检查HA状态,确认“HA Enabled Heartbeat Up” and “HA-state in sync”。 4. 使用命令slotShow检查所有的CP Blade都处于Enabled状态。 swDir:admin> slotShow Slot Blade Type ID Status --- 1 SW BLADE 17 ENABLED 2 SW BLADE 17 ENABLED 3 SW BLADE 17 ENABLED...
2.2.3.5. portshow 命令 作用:查看交换机端口状态 用法:portshow <端口号> IBM_3534_FC_Switch:admin> portshow 3 portFlags: 0x23805b portLbMod: 0x0 PRESENT ACTIVE F_PORT G_PORT U_PORT LOG IN NOELP LED ACCEPT portType: 4.1 portState: 1 Online portPhys: 6 In_Sync portScn: 6 F_Port ...
portPhys: 6 In_Sync portScn: 6 F_Port portRegs: 0x81000000 portData: 0x102def70 portId: 010000 portWwn: 20:00:00:60:69:c0:65:74 portWwn of device(s) connected: 50:06:0b:00:00:22:82:08 Distance: normal Speed: N2Gbps Interrupts: 24 Link_failure: 0 Frjt: 0 Unknown: 3 Loss...
Port state – 可能的端口状态包括: No_Card – 该槽位没有连接任何卡 No_Module – 该端口没有 GBIC 模块 No_Light – 该端口没有收到光信号 No_Sync – 收到光信号但是没有同步 In_Sync – 收到光信号并且正在同步 (铜口显示为 Sync, 光纤将显示为 Online) Laser_Flt – 该模块收到激光错误(GBIC...