打印/制作klicky probe 2.0的probe,过程不再赘述。但应该选用触发压力小的微动(软的微动)如鼠标微动。 修改klipper_z_calibration下的z_calibration.py内calibrate_z函数,如果最开始没有使用安装脚本而是直接复制的文件,则修改klippy/extras/z_calibration.py文件。之后记得要重启一次树莓派。 修改y_offset为0,一般在p...
// PID_CALIBRATE: Run PID calibration test // PROBE : Probe Z-height at current XY position // PROBE_ACCURACY: Probe Z-height accuracy at current XY position // PROBE_CALIBRATE: Calibrate the probe's z_offset // QUERY_ADC : Report the last value of an analog pin // QUERY_ENDSTOPS:...
The calibration is started by using theCALIBRATE_Zcommand. There are no more parameters. If the probe is not attached to the print head, it will abort the calibration process (if configured normaly closed). So, macros can help here to attach and detach the probe like this: [gcode_macro ...
Added compatibility for newer Klipper versions. v0.4 The "calibrate_z:probe_bed_x|y" settings can be omitted in the configuration and the "mesh:relative_reference_index" of the bed mesh is taken as default instead. v0.3 A new option to first probe down fast before recording the probing sa...
heater_pin是加热引脚。sensor_pin是测温引脚。sensor_type常用的一般都是3950。如果你用的不一样,可以去http://www.klipper3d.org/Config_Reference.html#temperature-sensors找。 下面是调平探头[probe]。探头用的是TL-Q5MB2,我在第一篇介绍了选它的原因。就是想可以直连接口。但是测试的时候发现,这个信号引脚...
self.retries = probe.samples_retries if self.lift_speed is None: self.lift_speed = probe.lift_speed if self.clearance is None: self.clearance = probe.z_offset * 2 if self.clearance < 3: # clearance is deprecated if self.clearance is not None and self.clearance == 0: ...
6. Then follow this instructions for testing and calibrating your offset: [Test and calibrate a Z probe](https://duet3d.dozuki.com/Wiki/Test_and_calibrate_the_Z_probe) 7. After that send a G29 command to measure and save your mesh and use G32 at your start gcode so it home all ax...
实际上是我们使用的命令不对,对于使用默认Z限位方案的Voron2.4来说,我们应该使用Z_ENDSTOP_CALIBRATE命令而不是PROBE_CALIBRATE命令,配置文件中也给了我们充分提示: 首先我们通过控制台将打印头归零,然后将打印头移动到热床中间位置: 当然后执行Z_ENDSTOP_CALIBRATE命令: ...
BTW, I made the adxl345 to self-calibrate its freefall acceleration offset, so it will no longer depend on the correctaxes_mapparameter. And now other adxl345s (besides the one that is used as a probe) can be (again) connected on-demand. Also if the probe was disconnected and then re...
When the Klipperscreen macro for Z calibrate is done, it remarks out (comments out) the original default -0.25 value in a [probe] section in printer.cfg, and adds an override value of "#*# z_offset = -0.xxx" — ...but I cannot seem to get changes to z_offset to make any diff...