YASKAWA AC Drive V1000 service manual说明书用户手册.PDF,YASKAWA AC Drive V1000 Compact Vector Control Drive Technical Manual Type: CIMR-VA , CIMR-VT Models: 200 V Class, Three-Phase Input: 0.1 to 18.5 kW 200 V Class, Single-Phase Input: 0.1 to 3.7 kW 400
Using this ® option card and an EtherCAT master can; • operate the drive • monitor the drive operation status • read or modify drive parameters. The SI-ES3 option provides instant connectivity to an EtherCAT® network for the YASKAWA V1000 drive. The option contains support for the...
YASKAWA AC Drive-V1000 Compact Vector Control Drive Quick Start Guide Type: CIMR-VU Models: 200 V Class, Three-Phase Input: 0.1 to 18.5 kW 200 V Class, Single-Phase Input: 0.1 to 3.7 kW 400 V Class, Three-Phase Input: 0.2 to 18.5 kW To properly use the product, read this manual ...
• Do not change the Inverter parameters or the MEMOBUS data using other methods, such as communication connection terminals or communication cards, while using DriveWizard. If the Inverter parameters or the MEMOBUS data are changed using other methods while using ...
Revision 3 February 24, 2021 Page 1 of 5 When first configuring the V1000/A1000/GA500/GA800, there are a few parameters that need to be changed. The key parameters that require a change from default are listed below. Make sure the IP address being set is reachable from the MPiec contro...
◆ Quick Reference Drive a Synchronous PM Motor L1000A can operate synchronous PM motors. Refer to Flowchart C: Auto-Tuning for PM Motors on page 110. Perform Auto-Tuning Automatic tuning sets motor parameters. Refer to Types of Auto-Tuning on page 112. Maintenance Check Us...
V1000 A1000 U1000 Z1000 GA800 OLVPM (A1-02=5)Remarks General Features Variable torque application HVAC Pumps Low dynamics Current stabilization algorithm Starting torque 100% @ 5% speed V1000, Z1000: 50% @ 10% speed Speed control range 1:20V1000, Z1000 1:10 Speed accuracy ±0.2% En...
Yaskawa designed the iQpump Micro with pump service operators and pump system owners in mind. iQpump Micro offers ease of setup and comprehensive pump and motor protection features. The integrated pump specific software and set up parameters allow the operator to program control values for a wide...
Dynamic Search for Drive Parameters Initialize Drive Function Ethernet Network Configurator 6-Channel Real-time Trend-Recorder with record, playback and trigger function 4-Channel Real-time Monitor Panel with auto and manual scaling function Status and Diagnostics Panel to view active drive status and ...
•Z1000•P1000•U1000•V1000•J1000 Background Increasing pressure to control costs and increase efficiency often means products are selected to perform the job at hand with little or no excess capacity. Days of over-sizing products to insure adequate operation are becoming rare due to ...