XPSPEAK version 4.1 (XPSPEAK41.exe) latest version 4.1, Free, fully featured, software for the analysis of XPS spectra written by Raymund Kwok...
XPSPEAK (XPSPEAK41.exe) Free, fully featured, software for the analysis of XPS spectra written by Raymund Kwok.XPSPeak is a XPS Peak Fitting Program...
The XPS spectra of samples at calcination temperatures 200, 300 and 400°C were analyzed by peak41 software. The complete information from XPS spectra were obtained with Shirley-type background correction. The chemical composition of NiO nanoparticles was identified after deconvolution and fitted with...
Peak power >80 MW >150 MW >150 MW Spectral bandwidth < 7.5 nm < 7.5 nm < 7.5 nm Pulse selection options Single-shot to 1MHz Single-shot to 1MHz Single-shot to 1MHz Beam quality, TEMοο M² <1.2 M² <1.2 M² <1.2 PER >22 dB vertical >22 dB vertical >22 dB vertical...
All parameters are free-programmable in physical units (for instance the bandwidth of the velocity loop). Furthermore, the XPS-DRV03 features individual limits for the rms current and the peak current. The XPS-DRV00 pass-through module can be used to pass control signals to other external ...
Upon further raising the reduction temperature to 873 K, this 2p3/2 peak at 852.0 eV becomes broader and more intense, indicating a higher concentration of Niδ− species in the catalyst. View Download Figure 3 (Color online) Quasi in situ XPS spectra of (a) Ni 2p and (b) Ti...
While playing taxing games, it will peak around 71C° while the GPU averages 76C°. Pleasingly, there is no thermal throttling in any scenario I have tested. The advantage of the Skylake processors’ smaller die size is apparent in the thermal efficiency they exhibit in a laptop this thin....
to the 15W TDP. Undervolting produces only a slight increase in performance, but it can’t make a major impact. The Iris 540 chip does have the potential to be much faster—but TDP constraints mean that the CPU and GPU just can’t be both operating at peak performance at the same ...
The obtained values of C sp3 resulting from the X-ray excited C KLL Auger spectra were compared to the respective values resulting from the C 1s peak fitting, derived and reported previously [21], [46], [47], [48], [49], [50], [53]. The average values of parameter D and their ...
or Tougaard methods, and enter lower/upper bound estimates for fit parameters. Run optimization algorithms to achieve the best fit. Fits can be exported or saved, and reloaded into the application for future use. Simple and efficient to use for fast peak fitting and chemical shift identification...