The wicking of the patch allows for improved temporal measurements in comparison to either direct skin contact or to the use of a single piece of absorbent material (Fig. S8). Options are also available for direct integration with microfluidic thread structures, or into more sophisticated ...
aTime-dependent responses (capacitance) andbpiecewise fitting of the response of PAM/Tapioca DN hydrogel bulk and film sensors.cSensitivity comparison of the two hydrogel sensors.dDynamic response (capacitance) curves,epiecewise fitting of the response, andfsensitivity comparison of hydrogel film sensors...
signal recording took place without any glucose intake for 30 min. Simultaneously blood samples were obtained every 20 min using an Accu-Chek® Aviva glucose meter during the whole experiment. After capturing the signal without glucose intake, glucose feeding steps of 360 mL of saline solu...
A comparison between main wireless technologies is proposed, oriented towards medical applications. We focus on the performance and limitations of each wireless technology in WBAN systems. Besides the traditional wireless technologies, the WBAN perspectives of the 5G, B5G and 6G are presented, and an...
However, a comparison of BGM data downloaded from meters and insulin pumps of nonwireless patients indicated that their insulin pump data significantly underestimated the number of BGM readings conducted, as well as the number of low and in-range readings, while overestimating the number of very ...
Simulated efficiency comparison between conventional and proposed metamaterial inspired WPT systems during misalignment(a)Lateral Misalignment.(b)Receiver Separation misalignment inside the tissue.(c)Transmitter separation misalignment from the tissue.
Table 1 Comparison of the proposed rectifier with state-of-the-art implantable rectifiers. Full size table The simulated and measured RF-to-DC efficiencies of the rectifier against the operating frequency are portrayed in Fig.4. Evidently, the peak efficiency depends on the available input power....
, by using this shared secret key known only to the particular instance of gateway110and retrieving it for pairing purposes from trusted vault472. This embodiment avoids the need for vitals device130from having to re-pair itself with gateway110using short term keys and/or numeric comparison ...
55 4 Submit Document Feedback Product Folder Links: CC2674R10 Copyright © 2024 Texas Instruments Incorporated www.ti.com 5 Device Comparison RADIO SUPPORT Device CC2674R10 SWRS268B – DECEMBER 2022 – REVISED APRIL 2024 FLASH (kB) RAM + Cache (kB) GPIO PACKAGE SIZE CC1310 CC1311R3 CC...
R 0h Reserved R/W 0h Comparison address, UNKNOWN on reset. 0h = Breakpoint Comparator Register 1 compare disabled 1h = Breakpoint Comparator Register 1 compare enabled 30 CC23xx SimpleLink™ Wireless Microcontroller Unit SWCU193A – APRIL 2023 – REVISED AUGUST 2024 Submit Document Feedback...