We have had some feedback from clinical partners regarding setting of window for highlighting different organs. The window/levels are defined typically by window width (WW) and window level (WL). This is then used in the following formul...
See also:CT number,window level,window width. Synonym(s):fenestra 2.Any opening in space or time, particularly a critical interval within which a given event must, or cannot, occur. See also:CT number,window level,window width. 3.computed tomographythe range of CT numbers (in Hounsfield ...
AUTOMATICALLY SETTING WINDOW WIDTH/LEVEL BASED ON REFERENCED IMAGE CONTEXT IN RADIOLOGY REPORTA system and method for automatically setting image viewing context. The system and method perform the steps of extracting image references and body parts associated with the image references from a report, ...
encoded in the lookup table. To provide feedback to the user, the “window width” can be reported as the adjusted range of input values to the LUT, and the “window center” can be reported as the center value of that range.
encoded in the lookup table. To provide feedback to the user, the “window width” can be reported as the adjusted range of input values to the LUT, and the “window center” can be reported as the center value of that range.
All liver images were viewed in two different window settings, soft tissue window setting: window width (WW) of 350-400 Hounsfield unit (HU), window level (WL) of 35-50 HU, and liver window setting: WW of 150 HU, WL of 50-100 HU, at the workstation. Results: Out of 411 patients...
The excitation source was an 808-nm diode laser (RMPC lasers) with a linewidth full-width at half- maximum of 1.89 nm at an output power of 160 mW and filtered by an 850-nm short-pass filter (Thorlabs), a 1,000-nm short-pass filter (Thorlabs), an 1,100-nm short-pass filter (...
AUTOMATICALLY SETTING WINDOW WIDTH/LEVEL BASED ON REFERENCED IMAGE CONTEXT IN RADIOLOGY REPORTA system and method for automatically setting image viewing context. The system and method perform the steps of extracting image references and body parts associated with the image references from a report, ...
AUTOMATICALLY SETTING WINDOW WIDTH/LEVEL BASED ON REFERENCED IMAGE CONTEXT IN RADIOLOGY REPORTFIELD: medicine.;SUBSTANCE: group of inventions relates to medical equipment, specifically to means for diagnosing using tomographic imaging. Method for automatically setting an image viewing context includes ...