Acute stroke: improved nonenhanced CT detection—benefits of soft-copy interpretation by using variable window width and center level settings Radiology (1999) D. Shen et al. Deep learning in medical image analysis Annu Rev Biomed Eng (2017) There are more references available in the full text ...
We have had some feedback from clinical partners regarding setting of window for highlighting different organs. The window/levels are defined typically by window width (WW) and window level (WL). This is then used in the following formul...
Automatic window width / level setting based on reference image context in radiology reportsA system and method for automatically setting an image display context. The system and method includes extracting an image reference and a body part associated with the image reference from the report, mapping...
See also:CT number,window level,window width. Synonym(s):fenestra 2.Any opening in space or time, particularly a critical interval within which a given event must, or cannot, occur. See also:CT number,window level,window width. 3.computed tomographythe range of CT numbers (in Hounsfield ...
All liver images were viewed in two different window settings, soft tissue window setting: window width (WW) of 350-400 Hounsfield unit (HU), window level (WL) of 35-50 HU, and liver window setting: WW of 150 HU, WL of 50-100 HU, at the workstation. Results: Out of 411 patients...
To change the window width and level values for the displayed image, the user would push the left mouse button, while simultaneously moving the mouse (the position of the mouse cursor is sensed, in order to derive the window and level values, with the x axis representing level, and the y...
encoded in the lookup table. To provide feedback to the user, the “window width” can be reported as the adjusted range of input values to the LUT, and the “window center” can be reported as the center value of that range.
4 Institute of Super- microstructure and Ultrafast Process in Advanced Materials, School of Physics and Electronics, Central South University, Changsha 410083, China. 5 Department of Radiology and Bio-X Program, School of Medicine, Stanford University, Stanford, California 94305, USA. * These ...
AUTOMATICALLY SETTING WINDOW WIDTH/LEVEL BASED ON REFERENCED IMAGE CONTEXT IN RADIOLOGY REPORTA system and method for automatically setting image viewing context. The system and method perform the steps of extracting image references and body parts associated with the image references from a report, ...
AUTOMATICALLY SETTING WINDOW WIDTH/LEVEL BASED ON REFERENCED IMAGE CONTEXT IN RADIOLOGY REPORTA system and method for automatically setting image viewing context. The system and method perform the steps of extracting image references and body parts associated with the image references from a report, ...