The L T measured with WB lactate was no different from that with PL lactate (5.4卤1.7 vs. 5.5卤1.8 min, P> 0.05). In summary: The pattern of change in plasma lactate is analogous to that in whole blood in response to a ramp-pattern exercise. The L T in plasma lactate is not ...
In the present work, we describe an ultrasensitive and cost-effective PEF-based immunosensor—consisting of 2D AuNP array functionalized by PIT—able to detect proteins at femtomolar level in whole human blood. Specifically, we measured the concentration ofPlasmodium falciparumlactate dehydrogenase (PfLD...
purine, and nucleotide metabolism (all OPLS-DAp < 0.001). Acute changes in the metabolic phenotype from rest to post-exercise could discriminate athletes with: (1) higher vs. lower peak blood lactate concentrations; (2) superior vs. inferior...
Plasma lactate increased by 0.2 mM (Figure 5F), but was unassociated with an acidosis in blood gasses (pH, bicarbonate, or pCO2; Figure S5F). During a primed-continuous intravenous infusion of [U-13C6]-D-glucose at each time, the study plasma M+6 glucose enrichments groups were ...
Reliability of point-of-care hematocrit, blood gas, electrolyte, lactate and glucose measurement during cardiopulmonary bypass Perfusion (2006) J. Steinfelder-Visscher et al. Conductivity-based hematocrit measurement during cardiopulmonary bypass J Clin Monit Comput (2007) N.R. Connelly et al. The us...
(min) Packed red blood cell transfusion (IU) Fresh-frozen plasma transfusion (ml) EAD-O MEAF 64 [52–73] 24.9 [23.1–27.1] 26 [15–59] 29 [20–64] 35 [14–70] 65 [51–106] 150 [144–154] 0.9 [0.6–1.2] 4 [2–6] 485 [405–576] 40 [32–51] 1.76 [...
Blood samples were taken before and after training to measure changes in basal adrenal hormones (adrenaline, noradrenaline, and cortisol). Sleep patterns were also assessed during training via wrist actigraphy. As compared with CON, the administration of WBC after each training session during four ...
ASSESSMENT OF BLOOD LACTATE: DIFFERENCES BETWEEN PLASMA AND WHOLE BLOOD USING REFLECTANCE SPECTROPHOTOMETRY AND AUTOMATED ANALYZER: 95Millard-Stafford, M. L.Snow, T. K.Rosskopf, L. B.Sparling, P. B.Medicine & Science in Sports & Exercise
(day 58 and day 83, respectively) revealed no abnormalities. The analyses of serum, plasma and EDTA blood samples revealed transient trends in clinical chemistry, coagulation, and hematology parameters over time. The changes observed in these parameters were within the range of normal values and ...
The physiological explanation for the upper vs. lower body differences in response to increased intensity in the present study is difficult to define, since body core temperature and local skin temperature and blood flow were not measured. Perhaps, some insights may be gleaned from Smith and Haven...