For example, if the system is designed for maximum pipe length and the refrigerant charge is 6kg, safety measures are required for rooms of 15m² or less.1. Shut off valve kit UTP-GX027A, UTP-GX060A Block the path to prevent refrigerant flow in the event of a refrigerant leakage....
VRF outdoor units were traditionally only air-sourced. In 1990, water-cooled outdoor units were introduced to overcome the challenges with maximum refrigerant pipe length and provided more flexibility. Water-cooled VRF units use condenser water for heat exchange, therefore they can be installed in ...
Maximum elevation m Refrigerant charge (pre-charged pipe length) kg(m) Additional refrigerant charge g/m Refrigerant Compressor Dimensions Height mm Width mm Depth mm Weight Kg * See Technical Catalogue for Restrictions 1 ~ 230 V 50H 1-2* 90-110% 5,00 (2,20 - 5,60) 5,60 (2,20...
Maximum Airflow Rate 11000 Featured Function Oil balance pipe not required Power supply 380-415V Refrigerant R410a Cooling capacity 28kw Airflow rate 110003/h Sound pressure level 58dB(A) Function Cooling Heating Ambient temp. operating range ...
Thanks to its extended piping length, the DVM S ECO offers maximum flexibility when it comes to deployment. It allows for a level difference of up to 50m between indoor and outdoor units, and a pipe length up to 150m. This generous variation lets businesses customise systems to operat...
A multi-position air handler with integrated DX kit for maximum convenience View Top Flow VRF Gen2 VRF (Heat Recovery VRF) 6-36 Ton Heat Recovery Systems Heat recovery units can heat and cool spaces simultaneously View VRF Indoor Units
Min. order: 1 set Easy Return Midea floor standing Industrial 30 ton central air conditioner For project $14,000.00 - $18,000.00 Min. order: 1 set Easy Return Midea 25ton long piping capability industrial air conditioners medea r410a multi inverter hvac system central air conditioning ...
1.2 140 × 117 × 43 200 1 Modbus communication specifications Transfer mode Communication speed Data bit Parity Stop bit Network Maximum cable length RTU mode 9600/19200bps 8 even/odd/none 1/2 (no parity) RS485 1000m (3280 ft) MODBUS® Convertor UT Y-VMG X 9Max. Controllable units ...
Standard maximum capacity comparison of LG chiller and VRF single units. Q. Which system type is more efficient in terms of both initial investment and operating costs? Lee: When you compare only the cost of the product equipment, the initial investment is actually similar. However, because a ...
Thanks to its extended piping length, the DVM S ECO offers maximum flexibility when it comes to deployment. It allows for a level difference of up to 50 m between indoor and outdoor units, and a pipe length up to 150 m. This generous variation lets businesses customise systems to operate...