54038 - Vivado - ERROR: [Common 17-161] Invalid option value 'BITSTREAM.CONFIG.UNUSEDPIN' specified for 'name' Description I have tried to add the following command in the Tcl console: set_property BITSTREAM.CONFIG.UNUSEDPIN PULLNONE [current_design] ...
Critical Warning: [Common 17-161] Invalid option value '#' specified for 'objects'. ["F:/test_proj/test.xdc":2] Example constraint that produces this Critical Warning: set_property PACKAGE_PIN E19 [get_ports CLKIN_P]# test comment ...
54038 - Vivado - ERROR: [Common 17-161] Invalid option value 'BITSTREAM.CONFIG.UNUSEDPIN' specified for 'name' Description I have tried to add the following command in the Tcl console: set_property BITSTREAM.CONFIG.UNUSEDPIN PULLNONE [current_design] ...
62472 - Vivado Simulation 2014.3 - ERROR: [Common 17-161] Invalid option value '' specified for 'object'. Description I am trying to run a Behavioral simulation on a project and receiving the following results: launch_simulation INFO: [USF-XSim-27] Simulation object is 'sim_1' ...
70893 - 2018.1 Vivado - Setting tcl.PRE/POST properties from the Property tab issuing wrong commands - ERROR: [Common 17-161] Invalid option value '' specified for 'of_objects'. Description When I attempt to set a pre or post Tcl file for a created run in Vivado, it fails with the ...
Usingthe-no_fanout_optOption Inthefanoutoptimizationphase,thecercanreplicateregistersdrivinghigh-fanous (Fanout1000,Slack2.0ns)orregistersdrivinswithdedicatedblockloads(BRAM, FIFO,URAM,DSP)thatarecedfarapart(Slack0.5ns)swithaMAX_FANOUT propertyvaluethatislessthantheactualfanoutoftharealsoaddedtothefanout optimi...
Each option has one and only one value. 3. The format of the list is: … 4. Line 5: The Tcl array options is initialized with the default values. 5. Line 7: The args variable overrides the default values 6. Line 9-10: The value of each option is being read with $options(...
Each option has one and only one value. 3. The format of the list is: expanse="page"> 4. Line 5: The Tcl array options is initialized with the default values. 5. Line 7: The args variable overrides the default values 6. Line 9-10: The value of each option is being read with ...
A dialog box allows you to specify the value for each option. When you click OK, the tool does the following: 1. Validates the syntax. 2. Applies the syntax to the memory. 3. Adds the new constraint at the end of the spreadsheet. 4. Adds the new constraint at the end of your ...
(Answer Record 58666) MIG 7 Series DDR3/DDR2 - MIG GUI allows higher value (400MHz) than the DS191 specification (333Mhz/667 Mbps) for Kintex-7 FBG in -1 for DDR3L (1.35V IO) 2.0 Rev 1 2.0 Rev 3 (Answer Record 57221) MIG 7 Series DDR3 RDIMM - non-ideal setting for RC3/4...