Background/objectives: This research study compares the performance of a three-phase single active bridge DC-DC converter with several operating modes along with vector groups in order to present the importance and applications of transformer vector groups in the electrical network system. Methods/stati...
Automatic transformer 1/10 turn ratio test equipment Main technique index sign 1.Ratio measurement range:1-10000 2.Group measurement:1-12 (12 vector groups) 3. Phase measurement error:1 degree 4. Ratio measurement error:0.2 class 5.Power supply:AC220V ± 10%, 50Hz ...
1) Transformer Ratio: 1--10000 2) Group: 1--12 point (12 vector groups) 3)Accuracy: 0.2 class 4)Power supply: AC220V 10%, 50HZ 5) Environment temperature : -5ºC--40ºC 6) Humidity: <85% 7) Size: 430*320*215mm 8) Weight: 10kgs ...
A three phase transformer is one of the vital apparatus in the power systems. In addition to the voltage ratios and KVA ratings, one of the most important specifications is the transformer vector group. A transformer vector group is required to be known from the angle of parallel operation of...
在这项工作中,作者分析了 Point Transformer 的局限性,并提出了 Point Transformer V2 模型,克服了先前工作的局限性。首先提出了组向量注意力 group vector attention ,继承可学习权重编码和多头注意力的优点。作者还通过额外的位置编码乘子 position encoding multiplier 加强了注意力的位置信息。此外,作者设计了新颖且轻...
testing of SVM are obtained by measurement on two groups of transformers (one is a classic 20 kV transformer and the other is a model transformer) under intact condition and under different fault conditions (axial displacement, radial deformation, disc space variation and short circuit of winding)...
The MLP-like structure has re- cently shown the ability to rival the Transformer with sim- ple architecture. In the image field, MLP-Mixer [37] first use the combination of Spatial MLP and Channel MLP. The subsequent works [3] [18] reduce computational complex- ity...
LlamaIndex is a data framework for your LLM applications - llama_index/CHANGELOG.md at feature/lindormsearch-vector-db · Rainy-GG/llama_index
Transformer Ratio 0.9--10000 Group 1--12 Point (12 Vector Groups) Environment Temperature -5--40 Humidity <85% Certificate ISO Standard IEC Neight Weight 0.8kgs Gross Weight 5kgs Measuring Size 200*100*60mm Applicated Field Tranformer Winding′s Ratio Measuring ...
By this the column Transformed is displayed in the signal view of Data Mapping editor (DaVinci Developer), which shows the type of transformation configured for the corresponding signals/signal groups. Note: the main (End-to-End) transformer configuration is part of the communication...