Added the "Installing a Power Module" section, the procedure for updating the software version during the first power-on, and the section about FQA spare part authorization. Change the PVC to the PC. Updated the "UPS Maintenance" and "Lead-Acid Battery Maintenance" sections. 07 2023-03-20...
Figure 5-1 AC input, output, and battery wiring diagram Starting the UPS Using Mains Power Cold-Starting the UPS Using Batteries 5.2.1.1 Starting the UPS Using Mains Power Procedure Switch on the external battery circuit breaker (if any). Switch on the external AC input circuit breaker Km fo...
replacement shall be Eaton Corporation property and Eaton Corporation shall promptly and in accordance with applicable regulations dispose of such parts. Optional Services (performed at the same time, if purchased separately, as applicable) • Capacitor, Fan, and Battery Replacement Services • Energy...
2. Battery maintenance only be operated by professional personel who have barrtey knowledge. 3. There is risk of electric shock and short circuit the battery current danger. To avoid electric shock injury accident in the replacement battery, please observe the following warning: A. Do not wear ...
需要金币:*** 金币(10金币=人民币1元) APC Galaxy PX UPS Operation说明书用户手册.pdf 关闭预览 想预览更多内容,点击免费在线预览全文 免费在线预览全文 APCGalaxyPXUPSOperation说明书用户手册用户手册产品说明书使用说明文档安装使用手册 Galaxy PX UPS Operation 06/2020 Legal Information The Schneider Electric ...
Battery seems to have solved the problem with my TrippLite G100UB UPS. No fault of hte battery but, I did discover that this model of the TrippLite does have some wacky reset procedure, you have to let it charge the battery turned off with nothing plugged into the unit and then ...
Step B Disconnect the battery cable terminals before removing the battery module from the UPS. Note: The red cable connects to the red color- coded terminal; the black cable connects to the black color-coded terminal. This will be impor- tant during the battery replacement procedure. Battery ...
(e.g. is charging but battery too low to guarantee safety to the load) */ if (flag_isset(ups->status, ST_FSD)) return 1; /* not OB or not LB = not critical yet */ if ((!flag_isset(ups->status, ST_ONBATT)) || (!flag_isset(ups->status, ST_LOWBATT))) return 0...
Replacing the Battery Module This UPS has an easy-to-replace, hot-swappable battery module. Replacement is a safe procedure, isolated from electrical hazards. You may leave the UPS and connected equipment on during the replacement procedure. Once the batteries are disconnected the connected equipment...
It is recommended that you remove the battery before attempting to install it in the rack. See ìBattery Replacement Instructionsî on page 11 for the procedure. To Install the UPS as a Tower Configuration For stability, the UPS is shipped with stabilizing feet. Removal of the feet in a ...