Fully Populated UCS X9508 Chassis Approximately 400 lbs (181.43 kg) depending on models and options selected 1 The system weight listed here is an estimate for a fully configured system and will vary depending on the devices installed. Environmental Specifications Table 3. Environmental Specifi...
If fewer than six power supplies (PS) are configured in grid redundant mode, they should be equally distributed between the grid 1 and grid 2 slots. Removing a Power Supply Caution If you are using the Cisco UCS X9508 server chassis with one power supply, which is a ...
12 years ago, our 6RU blade chassis had enough space to power, cool, and provideUnified Fabricconnectivity for eight servers. The new UCS X9508 chassis still has eight slots, but times have changed. These slots will hold compute nodes and non-compute nodes in the future. Server subsystems ...
These playbooks have been modified to add support for Cisco UCS X-Series Direct with the Cisco UCSX-S9108-100G Fabric Interconnects inserted directly into the Cisco UCSX-9508 Chassis. This topology is shown below. Set up the execution environment To execute various ansible playbooks, a linux...
UCSX-9508-D UCS X9508 Chassis Configured UCSX-215C-M8-U (Paid Node) UCSX-215C-M8-FRE (Free Node) Cisco UCS X215c M8 Compute Node without CPU, memory, drive bays, drives, VIC adapter, or mezzanine adapters (ordered as a UCS X9508 chassis option) UCSX-440P-NEW-D UCS...
Cisco UCS X9508 Server Chassis Installation Guide --- Overview Cisco UCS X9508 Server Chassis Installation Guide --- Installation Cisco UCS X9508 Server Chassis Installation Guide --- Installing and Removing Components + Show 2 More Contact Cisco Open a Support Case (Requires a Cisco Service Cont...
The Cisco UCS X9508 Chassis and Cisco UCS X210c M6 Compute Nodes are automatically discovered when the ports are successfully configured using the domain profile as shown in Figure 38, Figure 39, and Figure 40. Figure 38. Cisco UCS X9508 Chassis Front View Figure 39. Cisco UC...
The Cisco UCS X9508 Chassis is configured with 8 x X210c Compute Node blades. Each blade is populated with 6 x 960 GB SAS SSDs, and a total of 48 12G SAS SSDs are configured on the eight blades. The graphs below show the scaling of per...
The Cisco UCS X9508 chassis and Cisco UCS X210c M6 Compute Nodes are automatically discovered when the ports are successfully configured using the domain profile, as shown inFigure17,Figure18, andFigure19. Figure 17.Cisco UCS X9508 Server Chassis (front v...
The Power Entry Module (PEM) for a small number of UCS 9508 units might not be secured in the chassis and could be pulled out when power cord is unplugged from the chassis. Caution: Do NOT remove the AC cord at the chassis end until the remediation has been applied. Background Cisco ...