COMPOSITION of feedsGAS absorption & adsorptionVAN der Waals forcesRESERVOIR rocksFlue gas generated by power plants is considered one of the primary sources of CO2 emissions. Flue gas can be injected into depleted gas reservoirs to minimize the impact of CO2 and other pollu...
Flue gas Composition (mol%) C1: 85.1, C2: 5.6, C3: 2.1, n-C4: 0.565, i-C4: 0.365, n-C5: 0.145, i-C5: 0.185, C6: 0.12, C7: 0.05, C8: 0.02, C9: 0.01, N2: 3.2, CO2: 2.2, H2S: 0.3,Benzene: 0.0048, Toluene: 0.003, COS: 0.0003, Mercaptans: 0.011, H2O: 0.011 Temperature...
Yet, their Hg isotope composition is still not reported. Here, we present the first onsite Hg isotope data for gaseous elemental Hg (GEM) and gaseous oxidized Hg (GOM) of flue gases from a typical lignite-fired power plant (CFPP). Significant mass dependent fractionation (MDF) and ...
Adsorption of Flue Gas on Carbonate and Sandstone Rocks at Typical Reservoir Conditions: Influence of Feed Compositiondoi:10.1007/s13369-024-08737-9CO2sequesteringCO2-EGRFlue gasN2SO2NOxIndiana limestoneAdsorptionFlue gas generated by power plants is considered one of the primary sources of CO2...
The flue gas composition is estimated by mass balance of a furnace based on stoichiometric reactions for combustion and glass melting. The quantity of air leakage is estimated based on gaps inside the furnace walland the differential pressure. The methodology is used for an industrial furnace where...
The flue gas composition is estimated by mass balance of a furnace based on stoichiometric reactions for combustion and glass melting. The quantity of air leakage is estimated based on gaps inside the furnace wall and the differential pressure. The methodology is used for an industrial furnace ...
Two characteristic physical parameters, namely, temperature and flue gas composition, are analyzed and compared in two scenarios (with and without the fire extinguishing agent). Two typical clean fire extinguishing agents (Novec 1230 and 2-BTP) are also applied in the fire extinguishing experiment. ...
To reveal the high-temperature corrosion mechanism of heating surfaces in the typical flue gas environment in the municipal solid waste incineration (MSWI) system, samples of 310S alloy, a commonly used boiler superheater heating surface material, were deposited with NaCl/50 wt.% K2SO4 and ...
Spatial variation of PCDD/F and PCB emissions and their composition profiles in stack flue gas from the typical cement plants in ChinaCement kilnDioxinPolychlorinated biphenylsEmission factorProfiles
Zou, L.L.; Ni, Y.W.; Gao, Y.; Tang, F.M.; Jin, J.; Chen, J.P. Spatial variation of PCDD/F and PCB emissions and their composition profiles in stack flue gas from the typical cement plants in China. Chemosphere 2018, 195, 491-497. [CrossRef] [PubMed]...