In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy,...
A major challenge in microrobotics is the control of multiple microrobots independently, especially identical microrobots. This paper proposes a novel actuation system for simultaneous planar position control of two identical magnetic microrobots. Four rotating permanent magnets are used to produce the ...
In the case of an assembly of non-interacting randomly oriented identical NPs, the hysteresis loop features a remanent magnetization Mr = 0.5 MS and a coercivity HC = 0.48 µ0HK. Accordingly, the loop area is reduced and it can be approximately estimated as A≈4μ0MrHC=2μ0MSHC=1.92...
The dimensions 1.15 m and 1.71 m of the welded square box cross-section of the both arches are uniform along the whole arch span except for the short part at the connection to the rigid beams on the arch ends (Figure 18). The main beams are supported by the vertical steel bar-type ...
Before comparing the various energy scales in PdCrO2, we first consider the case of isostructural PdCoO2, which has an identical crystal structure and Fermiology to PdCrO2 (above TN) but has a non-magnetic ground state. The temperature evolution of the Hanasaki coherence peak in PdCoO2 is...
A comparative analysis of magnetic specific heat in zero magnetic field revealed nearly identical contribution of short-range magnetic correlations and significant differences were observed at lowest temperatures. A phase transition to long-range order was observed in Cu(en)(H_2O)_2SO_...
‘ model. The two tablets are almost identical, which is why I’m reviewing them at the same time. The main difference is in the display category, as thePaperMatteedition has a new anti-reflective coating, which actually does wonders, but we’ll talk about that later. The only other ...
The device forming a homogeneous magnetic field uses two permanent magnets (1,2) spaced apart. Each magnet is shaped as a cone with its frustum cut off, and the bases of the cones face outwards away from each other. Both magnets are the same size. The included angle of the two cones ...
circled part in the figure.f3D schematic of the Hall bar structure of the Al2O3/Cr-TI/GaAs stack with a top Au gate electrode. A gate voltage ofVgcan be applied between the top gate and the Full size image Current-induced SOT is regarded as another efficient strategy to manipulate ...
The B distribution does not contain physical correlations, but has detector acceptance effects in φ identical to those in S. By taking the ratio, S/B in Eq. (3), the detector acceptance effects cancel out, and the resulting C( φ) contains physi- cal correlations only. To correct S(...