But before doing anything the Debug Window Pops up and shows theIfxCpu_Trap_BusErrorfunction. This also happens using other examples. Can anybody give me a hint what's wrong with my configuration? Hello Roland, even if this should not create any error, for correctness please note that the ...
Trap_busError on TriBoard TC275 User19008 Level 1 19 Mar 2020 I wanted to set into operation my new TriBoard TC275. First I created a new Project for TC27xTP_DC-step / KIT_AURIX_TC275_ARD_SB in AURIX Development Studio. Then I copied the sources of an existing Blinky_LED_1...
For the master mode there is per default a pull-up of 1K (R360) and a capacitor of 1nF (C304) on the BUS assembled. For using the LIN in slave mode the pull-up resistor R360 must be removed and maybe the capacitor changed to a smaller value (e.g. 220pF). The mentioned resistor...
BUS Control Signals Burst address advance output Address Valid Bus Request Output Hold Request Input Hold Acknowledge Wait Input Debug Signals Description Test Reset Test Clock Test Mode Select Test Data Input Test Data Output Trace Clock for OCDS Level 2 Test Mode Select Input TriCore Breakpoint ...
User's Manual 7-1 V 2.1, 2009-06 TriBoard TC176X/TC116X/TC1782/TC1387 Hardware Manual Connector Pin Assignment 7.1 TC176X/TC116X Connector / Top View BUS EXPANSION (X801,X901) GND 1 2 GND GND 3 4 GND 56 78 9 10 11 12 13 14 15 16 17 18 19 20 21 2...
The Clock group is a group that combines the eight clock bus output signals CLK[7:0] generated by the clock distribution cells. 时钟组是组合八个时钟总线输出信号CLK [7:0]由时钟分配单元产生。 The FPC/INT group is a group that combines the six level output signals SOL[5:0] of the FPCs...
(it can also be used to remove any delay between the data on the bus). The other BACON write is used to close the data transfer before the last data value is written (i.e. LAST=1). In this example the DMA transmit interrupt is used to to write the last BACON...
But before doing anything the Debug Window Pops up and shows the IfxCpu_Trap_BusError function.This also happens using other examples.Can anybody give me a hint what's wrong with my configuration?Hello Roland,even if this should not create any error, for correctness please note that the ...
(1) and TriBoard TC3X7 V2.0 Connector Pin Assignment 6.2 TC397/TC387/TC377/TC3E7 Connector / Top View BUS EXPANSION (X601,X701) GND 12 GND GND 34 GND 56 78 P21.6 P21.7 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 ...
(e.g. TC399) LIN Transceiver TX1 RX1 TriCore CPU RMII PHY Twisted Pair RJ45 HSCT - TX/RX BUS Burst FLASH 32 Bit BUS /CS0 or /CS1 FlexRay™ Transceiver BUS /CS0 or /CS1 WAKEUP SRAM 32 Bit 8 LED's (P33.4 up to P33.7, P20.11 up to P20.14) Serial EEPROM with EUI-48™ ...