Huazheng HZ2611 Transformer Low Voltage Short Circuit Impedance Test Device Winding Deformation Analyser $2,000.00 - $2,904.00 Min. order: 1 set Easy Return Tabletop Handheld Intelligent Three Phase Harmonics Power Quality Analyzer with Flicker and 3000A Current Probe ...
ITL is a UK leading low voltage Transformers Manufacturer. Our current and voltage transformers are suitable for a variety of LV, MV & HV systems.
mini pcb ei power transformer ei14 100w 12v 5a amplifier audio transformer voltage converter transformer, You can get more details about mini pcb ei power transformer ei14 100w 12v 5a amplifier audio transformer voltage converter transformer from mobile
A current mutual-inductor used in measurement in power system is that its no-load voltage ratio is matched based on the load current, if its variation exceeds the tolerant value, the ratio should be converted to meet the needs of measurement and protection which should be done when power ...
1)voltage transformer电压互感器 1.Site test and analysis of 220 kV metricalvoltage transformer;220kV计量电压互感器的现场测试及分析 2.Analysis ofvoltage transformersecondary loop grounding point;电压互感器二次回路接地点分析 3.Verifying the voltage ratio ofvoltage transformer(discharge coil) by method of...
GDHG-201P CT/PT Analyzer is designed for analyzing current transformers and voltage transformers of protection or measurement use, adopts high-performance DSP and FPGA, advanced manufacturing process to ensure stable and reliable product performance, complete functions, high degr...
For protection or energy measurement of the power system with rated frequency 50Hz rated voltage of 10kV and below, which LZZBJ9-10A installed in the center switchgear on other types of switchgear The current transformer is the pillar structure, the use of epox...
When a sinusoidal voltage Vp is applied to the primary with the secondary open-circuited, there will be no energy transfer. The impressed voltage causes a small current I0 to flow in the primary winding. This no-load current has two functions: (1) it produces the magnetic flux in the ...
5. The tester cantrack the transformer on-load tap-changer positionautomatically, and indicate the current tap point automatically. 6. The tester can display a transformer's first and secondary voltage Oscillograms and phase relationship. It can measure transforme...
Thus percentage reactance of a transformer is the percentage of phase voltage drop when full load current flows through it. Alternatively, percentage reactance (%X) can also be expressed in terms of kVA and kV as under : X=(%X)V100I=(%X)V×V100×VI=(%X)(V1000)(V1000)×1000100×(V1000)...