The head is configured for coupling with a ball configured for coupling with a socket implanted in an acetabulum of a pelvis of the patient during the procedure, thereby forming a total hip replacement. The head is anteriorly offset relative to the stem.Mccoy, Thomas Hatton...
System of femoral stems, acetabular components and surgical instrumentation to address situations during primary and revision total hip arthroplasty.
中英文字幕:炎性髋关节炎(Inflammatory Arthritis of the Hip) 中英文字幕:单极半髋置换术(Hip Hemiarthroplasty ,Unipolar) 中英文字幕:双动头半髋置换术(Hip Hemiarthroplasty ,Bipolar) 中英文字幕:髋部骨折(Hip Fracture) 中英文字幕:螺钉...
During the procedure, the femoral head and acetabulum are replaced with artificial components called prosthesis。 An artificial hip prosthesis consists a cup called the acetabular component and a metal stem called femoral component. 术中,用人工组件(假体)更换股骨头和髋臼。人工髋关节假体包括一个杯(髋臼...
Total hip replacement is a surgical procedure in which the damaged cartilage and bone is removed from the hip joint and replaced with artificial components. The hip joint is one of the body’s largest weight-bearing joints, located between the thigh bone (femur) and the pelvis (acetabulum). ...
Hip replacement surgery in general is a successful operation. The success of your hip replacement is measured by whether or not you are satisfied with the decrease in your overall pain and the increase in your mobility, as well as the durability of your implant over time. ...
A total hip replacement will provide complete or nearly complete pain relief in most patients. 对于大部分病人,全髋关节置换术能完全或几乎完全缓解疼痛。 QUESTIONS FOR YOUR DOCTOR 1. What guidelines should I follow prior to my proce...
To perform a total hip replacement, the hip joint must be opened and the hip dislocated. The work done inside to replace the joint is the same no matter what approach is taken. Find out more Surgical Approaches to the Hip with the following link Patient Info Hip Arthroscopy Arthroscopy, ...
A comparative experimental study of stresses in femoral total hip replacement components: The effects of prostheses orientation and acrylic fixation - Scie... The factors responsible for clinical stem failures of total hip joint prostheses were studied by instrumenting the Charnley, Mueller and Trapezoid...
Total Hip Replacement Parts Assembled Spyros Kallioras May 24th, 2013 Acetabular Cup Femoral Head Stem UHMWPE; Ultra-High Molecular Weight PolyEthyleneShow more... Download files Like Share 366 Downloads 6 Likes 4 Comments Details Uploaded: May 24th, 2013 Software: Solid Edge, Rendering,...