Dental implant parts titanium straight abutment rigid abutment For Straumann Systems $5.30 - $5.90 Min. order: 200 pieces Abutment implant titanium implant parts manufacturing grade 5 straight transfer abutment dental-abutment for Osstem low price $5.30 - $5.90 Min. order: 200 pieces Dental Titanium...
Material and methods Devices from 5 different dental implant manufacturers were evaluated, including 2 spring-type (Straumann, Implance) mechanical devices (MTLD), 2 friction-type (Biohorizons, Dyna) MTLDs, and 1 (Megagen) electronic torque-control device (ETLD). For each manufacturer, 5 devices...
In the wrenches that had been used for more than three years, 21.1% of samples showed an error of more than 10%, compared with 9.5% in wrenches that had been used for less than three years (P=0.39). At higher torques the Straumann system produced the least error and the Biohorizon ...
Titanium Angled Screw-retained Abutments Multi unit angled abutment for Straumann Bone level NC 17 degree D 4.6mm GH 2.5mm 4mm $21.50 Min. order: 6 pieces Implant Scs Manual screwdriver for Ratchet, extra short, length 10 mm T6 Torx star head fits to Straumann abutment screw $14.50 M...
Five implant systems were included in this study: Calcitek (Sulzer Calcitek, Carlsbad, Calif.), Steri-Oss (Bausch & Lomb, Yorba Linda, Calif.), Brånemark (Nobel Biocare, Gothenberg, Sweden), Alpha-Bio ([Spectra clone], Alpha-Bio, Petach Tikva, Israel), and ITI (Straumann Waldenburg,...
T6 Straumann 1. 8 kinds of implant systems were commonly used, with 16 branches in total; 2. Arbitrary switch of three working seeding types (machine, hand, wrench); 3. High temperature resistant sterilizing box is safer for repeated use; 4. Choos...
Objective Accurate delivery of torque to implant screws is critical to generate ideal preload in the screw joint and to offer protection against screw loosening. Mechanical torque-limiting devices (MTLDs) are available for this reason. In this study, the accuracy of one type of friction-style ...
The goal of this in vitro study was to determine the insertion torque/time integral for three implant systems. Bone level implants (n = 10; BLT - Straumann Bone Level Tapered 4.1 mm × 12 mm, V3 - MIS V3 3.9 mm × 11.5 mm, ASTRA - Dentsply-Sirona ASTRA TX 4.0 mm × 13 mm) ...
Removal torqueISQPurpose: To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive (R), Straumann, Basel, Switzerland), by evaluating removal torque and ...
A total of 6 different dental implant companies were represented (Astra Tech, Zimmer Dental, Biomet 3i, Straumann, Nobel Biocare, and Thommen Medical). All MTLDs had been in use for at least 6 months without being recalibrated, and all were tested to determine their accuracy in delivering ...