Luchetti WT, Copley LA, Vresilovic EJ, Black J, Steinberg ME (1998) Drain entrapment and titanium to ceramic head depo- sition: two unique complications following closed reduction of a dislocated total hip arthroplasty. J Arthroplasty 13:713-717...
Titanium Nitride Ceramic Films Against Polyethylene P Mj,G, Makris,B Ff 被引量: 124发表: 1995年 Cancer incidence in finnish hip replacement patients from 1980 to 1995: A nationwide cohort study involving 31,651 patients P Paavolainen,E Pukkala,P Pulkkinen,... 被引量: 0发表: 1999年 ...
With a normal implant longevity of 12 to 15 years, the majority of those that receive hip implants at age of 65 will require at least one revision surgery. Various metallic materials have been used for total hip replacements as well as other joint replacement surgeries, i.e., knees, ...
such as arthroplasty, hip joints, craniofacial, maxillofacial, dental implants, prostheses, and surgical instrumental applications, has increased [1]. Researchers estimate that demand for the replacement of hip and knee arthroplasties could reach 3.48 billion operations (673%...
decides their loadbearing capability, while the biocompatibility determines the success of implantation surgery. Metal, ceramic and polymer materials are currently the three most commonly used materials in the field of biomedical implants. Among those, titanium and its alloys possess excellent mechanical ...
A ceramic articulating system in total hip replacement thought to be superior to metal-on-polyethylene due to its extremely low coefficient of friction and potential for high resistance to wear. But ceramic is brittle, which makes it mec... Han, SungMin,Chu, JunUk,Chun, HeoungJae,... 被引...
It is coated in a porous alumina ceramic, to allow bone ingrowth for stabilisation. A ultra high molecular weight polyethylene (UHMWPE) liner fits inside the acetabular cup and provides the articulating surface for the femoral head. Figure 1. Implant components for a total hip replacement (photo...
Additionally, ceramic materials are used to produce metal-free (feldspar-based porcelain fused on YTZP infrastructure) and metal-ceramic (e.g., feldspar-based ceramic fused on metallic infrastructure) crowns (Fig. 1) [22]. For a given material, a variation of properties may exist as shown in...
The concept of stainless steel dual-mobility cup in total hip arthroplasty has demonstrated a very low incidence of long-term instability and a 98% survival rate after 12 years. We systematically implanted titanium alloy dual-mobility acetabular cups dur
Titanium nitride, abbreviated as TiN, is an extremely hard, synthetic ceramic material with hardness close to that of diamond. See also The mechanism of action of Dihexa Dihexa has become a pioneering peptide drug that can address neurodegenerative diseases, including Alzheimer's disease... Dec ...