Thermocouple reference junction: compensates for ambient temp changes.
(CJC) temperature variations Colour Codes Means of cable and sensor type identification; applied internationally according to appropriate standards Compensating Cable Used for connecting thermocouples to instruments; the conductors use low cost materials which have a similar ambient thermal emf relationship ...
1) Max. working temperature under oxidizing conditions: reducing conditions reduce max. temp. to 1900 °F (1038 °C).Performance Characteristics Maximum measured error Type Temperature range Standard Tolerance in % and °C* (whichever is greater)°C °F IEC class 1 IEC class 2 E 0 to 87...
Knowing the temperature is critical for the correct operation of everything from the human body to an automobile engine, and everything in between. We need to know the temperature of objects for an almost infinite number of purposes. Temperature is often an indicator that something is wrong: ...
Data sheet Date Page Sheath dia. 8 mm 3/8” (9.53 mm) 1/2” (12.70 mm) THERMO SENSOR 1. Operating conditions Permissible temperatures (°C) at measuring point -130 (type J)/ + 1100 (type K) Permissible temperature at process connection + 150 °C Ambient temperature at c...
Total Measurement Accuracy for Rapid Temperature Environment Ramps ±3°C maximum (8°C per minute ambient gradient) Dimensions 21.5 x 10.8 x 5.1 cm (8.5 x 4.25 x 2 in.) Weight 0.9 kg (1.95 lb) Measurement Performance Verification and Calibration -SD Option Performance is based on engi...
Therefore, if the ambient temperature is known, E0θ=Eθaθ+E0θa Eθaθ, is the measured EMF andE0θais the correction for the ambient temperature. The sum of these terms gives the EMF developed between 0°C and θ, allowing the tables to be used to determine the value of the unkn...
Before converting the thermoelectric voltages into equiva- lent temperature values, it is necessary to compensate for the difference between the thermocouple coldjunction side (device ambient temperature) and a 0°C virtual ref- erence. For a K-type thermocouple, the voltage changes by about 41µ...
Ambient Temperature -40℃ ~ +125℃ Storage Temperature -65℃ ~ +150℃ Max. Junction Temperature +150℃ Hot-Junction Accuracy ±1.5°C (Max.) Measurement Resolution Hot and Cold-Junctions: 0.0625°C (typical) Interface I2C I2C Address 0x60(default) / 0x67(optional) Size L: 40mm W: 20mm...
mm) digits and sign.Resolution: 1°.Memory Backup:Nonvolatile memory.Ambient Operating Temperature: 32 to 150°F (0 to 65°C).Storage Temperature: -4 to 176°F (-20 to 80°C).Weight:2.3 oz (65 g).Front Panel Rating: IP64.Agency Approvals: CE, FM, cUR, UR.Wiring Diagram ...