Nagano, K. Shimakura, Experiments to determine the convective heat transfer coefficient of a thermal manikin, Environ. Ergon. Elsevier Ergon. B Ser. 3 (2005) 423-429.Kuwabara K, Nagano K, Shimakura K, Mochida T
convective heat transfer coefficienthuman bodyoutdoor environmentThis study was conducted to determine the convective heat transfer rates (α c) of each part of the human body and of the whole body when a human is in a standing or sedentary posture in an outdoor environment. A wind tunnel ...
Furthermore, convective heat transfer coefficient, heat exchanger effectiveness, pressure drop, friction factor, under different conditions, are measured. The results demonstrate convective heat transfer coefficient of U-bend double pipe heat exchangers is enhanced by 35% for 1 MgO vol.% and 0.2 Cmc...
At a wind speed of 22 m/s, an increase in air temperature significantly reduces the convective heat transfer coefficient. Continuous airflow creates regions of low Reynolds numbers at the top of the rod and high Reynolds numbers along its sides, significantly enhancing the side convective heat ...
he measured convective heat transfer coefficient was between 6.2 and 7.6 W/m2C, with an average of 7.0 W/m2C. 展开 关键词: convective heat transfer coefficient natural convection Roman baths DOI: 10.1139/tcsme-2012-0029 被引量: 7 年份: 2012 ...
transfercoefficientandsurfacetemperaturewasinvestigatedwhenthecoolingwaterjetflowratevariedfrom0.9to2.1m·h一.Itis foundthattheconvectiveheattransfercoefficientisanonlinearfunctionofthesurfacetemperatureduringlaminarflowcooling.Within adistanceof70mmfromthestagnationline,thecoolingflowratehasnoeffectontheheattransfercoefficien...
Aim To improve the convective heat transfer coefficient in shell side, the most commonly used one is circular flange baffle. Determination of shell diameter Material selection Calculation of Resistance (Pressure Drop) of Fluid Passing through Heat Exchanger ...
In PDE tool What is the difference between... Learn more about convective heat transfer coefficient, heat source, heat flux Partial Differential Equation Toolbox
[15]measured the forced convective heat transfer in a bubbly flow, and reported that heat transfer coefficient rises up to 20 times higher when the gas volume fraction is 5% and the Rayleigh number ranges 4.0×109−1.2×1011. The paper is organized as follows. In Section 2, we explain ...
Inverse determination of convective heat transfer between an impinging jet and a continuously moving flat surface 2014, International Journal of Heat and Fluid Flow Citation Excerpt : The implemented method allows the transient cooling heat flux estimation from experimental rear face thermogramm. Ryfa an...