This paper presents the results of dynamic loading tests performed on concrete piles driven in very soft clay formation. The load transfer mechanism under blows of growing energy is described in terms of mobilized resistances (friction and point) and displacements at the top and at the base of ...
Static Load Tests of Posttensioned, Prestressed Concrete Road Bridge over Reservoir Water Plant The paper is presented the results of tests performed on four spans of a post-tensioned pre-stressed concrete road bridge located over a water plant on a w... A Mordak,Z Manko - International ...
Cyclic loading tests were performed on three one-storey steel frames and four three-storey concrete-filled tube (CFT) moment frames reinforced with a new type of earthquake-resisting element consisting of a steel plate shear wall with vertical slits. In this shear wall system, the steel plate ...
Tests were also performed for fresh concrete properties and compressive strength. Tests on compressive strength and abrasion were performed up to 365 days. ... R Siddique - 《Cement & Concrete Research》 被引量: 248发表: 2003年 Aggregate tests related to asphalt concrete performance in pavements ...
Li et al. [68] performed push-out tests on circular specimens of double-skin steel tubes filled with concrete after exposure to fire. Their investigation encompassed various parameters, including the duration of fire, cross-sectional hollowness, diameter-to-thickness ratio of the steel tube, and ...
ACI 236A members determined that, as no reference material was available one method to compare the rheometers would be to test them under the same conditions using the same concrete mixtures. A tentative analysis comparing two reometers was performed but did not involve most of the available ...
Tests on 21 concrete-filled steel tubes with circular sections were performed by Han [18], to investigate the influences of compaction method of concrete on the strength of concrete-filled steel tube. D/t ratio of the steel plate element is 30–35. As the experimental parameters, L/D ratio...
The present data paper describes an experimental campaign on five thin T-shaped reinforced concrete walls (DOI: 10.6084/m9.figshare.3490754.v2), which includes: details on the test units, materials, test setup, loading protocol, instrumentation, main features of each unit's response, organization...
Passively confined dynamic impact experiments on plain concrete specimens were performed employing steel and aluminum jackets with a 76.2-mm-diameter split... JC Gong,LE Malvern - 《Experimental Mechanics》 被引量: 59发表: 1990年 Numerical Analysis of Dynamic Direct Tension and Direct Compression Tes...
Fracture Behaviors of Dam and Wet-Sreening Concrete by Direct Tensile Test The direct tension tests were performed on prismatic specimens with no initial notch include dam concrete specimens which size is 250mm250mm500mm and wet-... Zhifang Zhao,B Pang,Zhigang Zhao - 《Key Engineering Materials...