Certificates for both calibrations are supplied together with the paired transmitter-sensor set Callendar Van-Dusen coefficients?The resistance at temperature t can be described this way R(t) = Ro*( 1 + A*t + B*t2 + C*(t-100)*t3) where Ro is the resistance at 0 °C and A, B and...
Certificates for both calibrations are supplied together with the paired transmitter-sensor set Callendar Van-Dusen coefficients?The resistance at temperature t can be described this way R(t) = Ro*( 1 + A*t + B*t2 + C*(t-100)*t3) where Ro is the resistance at 0 °C and A, B and...
Temperature transmitter calibration with sensor (with dry-well) Precision temperature measurement Verifying process temperature gauges Current measurement 4-20 mA (dc) 110 mA (dc) 24 mA (dc) Sourcing / simulation capabilities 15 V (dc) DC current: 4-20 mA ...
8.3 When ordering a transmitter product with a meter, the power supply of the transmitter should not be less than 15VDC. 8.4 When selecting digital display products, the working environment temperature range of the display head is -30℃~60℃. ...
8.3 When ordering a transmitter product with a meter, the power supply of the transmitter should not be less than 15VDC. 8.4 When selecting digital display products, the working environment temperature range of the display head is -30℃~60℃. ...
Improved quality assurance in between calibration intervals Robust design for permanently precise measurements even in demanding environments Transparent sensor monitoring thanks to logging of the diagnostic values Simulation function simplifies installation ...
environmental monitoring in calibration laboratories, industrial test cells, and weather stations. The PTU transmitter uses Vaisala's BAROCAP® sensor for pressure, HUMICAP® sensor for humidity, and a platinum RTD sensor for temperature-all known for their high accuracy and excellent long-term ...
Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms) Output Signal 4-20 mA /HART™ protocol Housing DIN B head mount Diagnostics Basic diagnostics including open/short sensor diagnostics Calibration Options 5-point calibration ...