loop control statement 循环控制叙述一种可执行叙述,用于指明循环控制下要执行的叙述,执行循环时要用到的参数,循环终止的条件及循环终止时控制转向何处。 loop control structure 【计】 循环控制结构 相似单词 loop n.[C] 1.环形,环状物,圆圈 2.环,圈 3.循环电影胶片,循环音像磁带 4.循环,回路,(程序中一...
Proportional Band(P):0~full range(ON/OFF Control when set to 0)Integration Time(I):0~3600Sec (no integral action when set to 0)Derivative Time(D):0~3600Sec(no derivative action when set to 0)Proportional Period:1~100SecOn-off control output hysteretic loop width:1~100°C(or ...
In this case one compensation for a control loop exerts harmful influence upon another control loop through the interaction. This paper presents a noninteracting PID control for a fluid temperature and liquid level interacting system. First, a precompensator is designed to remove the interaction of ...
Provide single and multi-loop PIDtemperature controllersfor simple on/off control or continuous PID control of temperatures. PID control uses an algorithm to automatically adjust heating/cooling outputs based on the difference between the measured temperature and setpoint. It is used in temperature contr...
Consequently the closed-loop system has desired characteristics; also this control strategy can solve the problem of the long-time delay of boiler superheated steam temperature. Finally the simulation results have shown the method has good dynamic and static control performances for this complicated ...
No system to date has demonstrated combined multi-modal deformation and temperature sensing for closed-loop control of a soft robotic manipulator with a single sensing element. In fact, the majority of thermally activated soft robotic systems are open-loop46,47,48,49. The manipulator consists of ...
Proportional Band(P):0~full range(ON/OFF Control when set to 0)Integration Time(I):0~3600Sec (no integral action when set to 0)Derivative Time(D):0~3600Sec(no derivative action when set to 0)Proportional Period:1~100SecOn-off control output hysteretic loop width:1~100°C(or...
Closed loop control EQUIPMENT FEATURES: 1.PID precise temperature control, heating platform automatically raises and lowers temperature according to a certain slope. 2.The high-quality configuration of the heating platform is clear at a glance, and the careful design is perfect....
As pointed out by Chen and Yu [16, 17], a heat integrated reactor via feed-effluent heat exchanger can easily become open-loop unstable for system with a high reactor gain (KR). Therefore, controllability problem may arise when we try to recover more heat form the hot gas of the ...
Also, significantly less fluid was infused through the DTA catheter compared with the control catheter (332.2 ± 120.8 ml vs. 785.2 ± 351.5 ml; p < 0.001). Maximum and average power delivery was significantly higher in the DTA group compared with the control arm (52.9 ± 2.1 W vs. 34.3...