2. Any other slave device on the I2C bus acknowledges an address byte with the R/W bit set high System Impact Can cause improper interrupt handling as the Master will see the interrupt as being cleared. System Workaround Minor software change: User must change command byte to something ...
You can find the latest release of this User's Guide at: http://www.kontron.com or at: ftp://ftp.kontron.ca/support/ For the circuits, descriptions and tables indicated, Kontron assumes no responsibility as far as patents or other rights of third parties are concerned. The following is ...
The system controller can reset the TCA9539-Q1 in the event of a time-out or other improper operation by asserting a low in the RESET input. The power-on reset puts the registers in their default state and initializes the I2C-SMBus state machine. Asserting RESET causes the same reset-...
In case of timeout or improper operation, the TCA9548A can be easily reset by setting the /RESET input to a low-level signal with IIC multiplexer breakout board. Similarly, power-up reset deselects all channels and initializes the I2C/SMBus state machine. Reset and initialization can be ...
6. Improper connection prevention lock mechanism: When connecting the holder, the lever is pushed into the end by rotating around the A axis to lock the holder securely. 3. DISCONNECTION OF CONNECTORS FOR CURTAIN SHIELD AIRBAG ASSY (TMC MADE), HORN BUTTON ASSY AND FRONT PASSENGER AIRBAG ASSY...
The system master can reset the TCA9534 in the event of a timeout or other improper operation by cycling the power supply and causing a power-on reset (POR). A reset puts the registers in their default state and initializes the I2C/SMBus state machine. The TCA9534 consists of one 8-...
following: • I2C Bus Pull-Up Resistor Calculation • Maximum Clock Frequency of I2C Bus Using Repeaters • Introduction to Logic • Understanding the I2C Bus • Choosing the Correct I2C Device for New Designs • I/O Expander EVM User's Guide 12.2 Receiving Notification of Documentation...
EN must be low for a minimum of approximately 60 μs to ensure a shutdown state. The system master can reset the TCA6507 in the event of a timeout or other improper operation by setting EN low for a minimum of approximately 60 μs. This has the same effect as a power-on reset ...
class II ESD Protection exceeds JESD 22 –±2000-V Human-body model (A114-A) – 200-V Machine model (A115-A) –±1000-V Charged-device model (C101) The system master can reset the TCA9548A in the event of a time-out or other improper operation by asserting a low in the RESET inp...