VREF (标称值) ———表 2. 支持的输出标准 输出标准 单端接口 LVTTL LVCMOS33 LVCMOS25 LVCMOS18 LVCMOS15 LVCMOS12 LVCMOS33,开漏 LVCMOS25,开漏 LVCMOS18,开漏 LVCMOS15,开漏 LVCMOS12,开漏 PCI33/PCIX HSTL18 Class I HSTL18 Class II HSTL15 Class I SSTL3 Class I, II SSTL2 Class I SSTL2 Class...
Input Reference Voltage (VREF1, VREF2) Each bank can support up to two separate VREF input voltages, VREF1 and VREF2, that are used to set the thresh- old for the referenced input buffers. The locations of these VREF pins are pre-determined within the bank. These pins can be used as...
AVR_JTAG10KR2810KR2710KR26NTC112RG112SW212JP11ADP13P14光敏热敏外部电压测试12SW3AIN01AIN12AIN23AIN34A05A16A27VSS8SDA9SCL10OSC11EXT12AGND13Vref14AOUT15VDD16U9pcf859110KR34470R36DS12DA10KR3310KR3810KR2910KR3110KR3710KR3910KR3210KR30AIN0AIN1AIN2AIN3AIN0AIN1AIN2AIN312JP13AD键盘接口P10P11P...
25 is not used to control the power of the pump light based on the momental wavelength, CPU 28 may be used, for example, to supply drive circuit 94 with an ON/OFF signal to shut down control in case of system failure, or to generate a reference voltage Vref (described in more ...
NP_Ctrl_Out—Internal control voltage scalar Parameters expand all Voltage reference (Vref)—Parameterization method Three-phase signals(default) |Magnitude-Angle (rad)|alpha-beta components|Internally generated Proportional gain—Proportional gain
Vref (pu) Reference voltage (pu) 19 Control (Shunt) Qm (pu) Shunt converter reactive power. A positive value indicates inductive operation. 20 Control (Shunt) Qref (pu) Reference reactive power (pu) 21 Control (Shunt) Id (pu) Direct-axis component of current (active current) flowing into...
V = Vref + XsI, where: V Positive sequence voltage (pu) I Reactive current (pu/Pnom) (I > 0 indicates an inductive current) Xs Slope or droop reactance (pu/Pnom) Pnom Three-phase nominal power of the converter specified in the block dialog box When the wind turbine is operated in va...
This input is visible only when theExternal control of reference voltage Vrefparameter is checked. m Simulink output vector containing six SVC internal signals. These signals are either voltage and current phasors (complex signals) or control signals. They can be individually accessed by using the ...
Frame NC0 2 +10Vref : 10Vdc 供给端子 3 Vin1 / Iin1+ 4 Iin1- Vin: 模拟量电压输入给定值输入 Iin: 模拟量电流输入给定值输入 0~20mA or 4~20mA 接线 4 5 DI 1: 6 DI 2: 7 DI 3: 8 DI 4: 9 DI 5: 10 COM: I/O 公共端子 0(4)~20mA 11 Iout 15 +24V 17 0V DO1.A 12 ...
Initially the source voltage is set at 1.004 pu, resulting in a 1.0 pu voltage at SVC terminals when the SVC is out of service. As the reference voltage Vref is set to 1.0 pu, the SVC is initially floating (zero current). This operating point is obtained with TSC1 in service and TCR...